SCL800 Stairclimber Service & Installation
Bulletin
Assembly
The SCL 800 ships boxed and requires
assembly. Two technicians are recommended.
Assembly hardware is SAE and installation
requires the following tools:
•
5/32” hex wrench
•
7/32” hex wrench or socket
•
1/2” wrench
Assembly guides ship with the unit. Care
should be taken when unboxing to gather all
parts and pieces prior to disposing of any
packaging. Assembly guides can be found on
each unit’s product page at Precor.com.
Once assembled, run the unit fully to check all
functions prior to putting into service
Console
The SCL 800 will only work with the P31
console.
Note: Some SCL 800 units were built with Version 1 of the P31 SCL 800 software
(305239-101 009). There is now a Version 2 that has minor updates, bug fixes and
has an updated build number from 009 to 012 (305239-101 012). If Version 1
software is found, use the CSAFE flashing procedure to update the console to Version
2.
To check the console software version on the console, access the information menu
and navigate to MAIN CONSOLE SW to view the current console software version. If
the build number is 009, flash the console using the 305239-101_bld012.a90
software file. P31 software can be found on the
General Release section under “Commercial UPCA SW (LED).”