Please retain these instructions after installation.

This  device  MUST  be  installed  by  a  qualifi ed  agency  in  accordance  with  the  manufacturer's  installation  instructions.  The  defi nition of 
a qualifi ed agency is: any individual, fi rm, corporation or company which either in person or through a representative is engaged 
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Installation Date:

Installed By:

Phone:

AUTOMATIC VENTILATION COOLING SYSTEM

Model: ventCool™

ITEMS INCLUDED IN KIT:

3-   ventCool™ Ventilation Cooling System Dampers of either 14”, 16”, 18”, or 20” diameter
1-   Integrated Ventilation Relay Control (IVRC) Damper Control Module 
3-  15 foot long Damper Cables with modular connectors
1-   TrioMAC8-2025 ™ Media Air Cleaner
1-   Venstar® T7850 Programmable Smart Thermostat with WiFi, touchscreen, and ventilation 

cooling function

1-   Venstar® ACC-TSEN Outdoor Temperature Sensor 
1-   50 VA, 24 Volt Transformer, junction box mounted

OPTIONAL COMPONENTS:

Healthy Home System™ Components for optional Fresh Air Mechanical Ventilation:

• HHSC+ Ventilation Control
• FAD Fresh Air Damper 
• Relief Duct Termination/screened cap

T Sensor temperature-sensing damper controller

COMPONENTS NOT INCLUDED:

•Outdoor Air Intake Ventilation Cooling Termination(s)
•Ductwork, fi ttings, 24V wiring & associated hardware
•Inlet termination for optional Fresh Air Mechanical Ventilation
•Air Handler and other HVAC system components

The Field Controls Healthy Home System™ ventCool™ is designed to be installed as part of the central HVAC forced-air duct system of 
a home or other suitable building, in areas where outdoor conditions may exist to cool the building with outdoor air, such as California 
climate zones 8 through 14.

California Energy Code (CEC) Title 24 provides large building energy reduction credits for Central Fan Integrated Ventilation Cooling
Systems (see Title 24 Residential Compliance Manual section regarding HVAC Requirements, Alternate Systems). Similar in cost and
function to a Whole House Fan, the Healthy Home System™ Automated Ventilation Cooling System monitors indoor and outdoor
conditions day and night, and automatically provides 100% outdoor air ventilation for cooling whenever outdoor conditions allow.

Содержание ventCool

Страница 1: ...r Temperature Sensor 1 50 VA 24 Volt Transformer junction box mounted OPTIONAL COMPONENTS Healthy Home System Components for optional Fresh Air Mechanical Ventilation HHSC Ventilation Control FAD Fres...

Страница 2: ...oling mode should occur based on indoor and outdoor temperature conditions Optional items not included are components for year round fresh air mechanical ventilation which may be directly integrated i...

Страница 3: ...4 The IVRC display will appear as shown in FIG 3 With optional Year Round Fresh Air Mechanical Ventilation Mechanical fresh air ventilation may be required by code for the purpose of providing adequa...

Страница 4: ...and flow rate in air ducts and their characteristics must be taken into account in duct flow calculations INSTALLATION Outdoor Air Inlet Termination s Outdoor Air Inlet Termination s Outdoor air inta...

Страница 5: ...included with the HHSC Attic installation in hot climates is not recommended see the Specifications section in the HHSC installation instructions for maximum service temperature and other limitations...

Страница 6: ...tification purposes when installation is complete HINT Mark connector housing of each damper harness for identification purposes when installation is complete Ensure that the system dampers are connec...

Страница 7: ...page 7...

Страница 8: ...page 8...

Страница 9: ...page 9...

Страница 10: ...page 10...

Страница 11: ...trical Connections of this manual Free Cooling cannot be enabled if Compressor Stages is set to 2 6 Set Free Cooling parameters on thermostat according to preference see thermostat instructions sectio...

Страница 12: ...d be energized with nominal 24VAC This should activate the ventCool ventCool active mode Note if Free Cooling has not been disabled the Y1 indicator will not illuminate and Y1 terminal will not be ene...

Страница 13: ...equired Inspect all cables and wiring for possible damage by animals or human activity Inspect the Outdoor Air intake and Relief Duct Termination Cap and clean if necessary Remove any debris or other...

Страница 14: ...dicator lamps illuminated on IVRC Check for nominal 24VAC on the CX and RX terminals 1 2 on the IVRC If there is voltage present and no damper output indicators are illuminated the IVRC must be replac...

Страница 15: ...ity Range Operating Humidity Range 5 to 90 RH non condensing Shipping Temperature Range Shipping Temperature Range 14 F to 140 F 10 C to 60 C Ventilation Cooling Air Dampers Ventilation Cooling Air Da...

Страница 16: ...52 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC P N 46696100 Rev B 03 16 WARRANTY WARRANTY For warranty information about this or any Field Controls product visit www fieldcontro...

Отзывы: