P/N 780101720 3/18 Rev A

www.fieldcontrols.com

This device MUST be installed by a qualified agency in accordance with the manufacturer’s installation instructions.The definition of 
a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, 
and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the 
precautions required, and has complied with all the requirements of the authority having jurisdiction.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Installed By:_______________________________________

Phone: _____________________

Installation Date: _____________

Please retain these instructions after installation.

The EvenAir H32 wiring hub is installed at the equipment. It is connected to the T32 or T32WF 
thermostat using the existing or new 4-wire thermostat cable that normally connects the thermostat 
to the equipment. The equipment is wired directly to the Wiring Hub, The upstairs sensor can be 
either a wired or wireless sensor. Wireless sensors require the ER1 radio module that plugs into the 
wiring hub. An outdoor temperature sensor can also be used to control fossil fuel heating in a dual 
fuel heat pump or to control a whole house fan or economizer. 

The EvenAir wiring hub can be used to control humidification and de-humidification, fresh air 
intake per ASHRAE 62.2, ERVs or HRVs, whole house fans and economizers.

COMPONENTS: H32 Wiring Hub

For Wireless Temperature Sensors
1 or 2 TSER Wireless Sensors
1 ER1 Plugin Radio Module

T32 or T32WF Thermostat
AMJ type Modulating Dampers
1 TS51 or 2 TS52 Wired Temp Sensors

H32

R

INSTALLATION MANUAL

WIRING HUB 

Model H32
PN 580011201

Wiring Hub
24VAC, 10VA

Made in USA

C

N

O

O

L

T

S

R

F I E L D

R

Содержание EvenAir H32

Страница 1: ...ing hub is installed at the equipment It is connected to the T32 or T32WF thermostat using the existing or new 4 wire thermostat cable that normally connects the thermostat to the equipment The equipm...

Страница 2: ...ith 2 stage heating and 2 stage cooling or conventional or dual fuel heat pumps with 2 compressor stages and 1 auxiliary heating stage One TS51 or two TS52 temperature sensors can be used in the sleep...

Страница 3: ...irflow control is disabled and airflow is no longer displayed on the thermostat User Airflow Control can be enabled using Option 52 User turns off automatic airflow control in the User Options Read en...

Страница 4: ...RS Ensure that damper installation does not cause obstruction to the damper blade WIRING Wiring Thermostat to H32 Wiring Hub Use the existing thermostat cable to wire the EvenAir commununicating therm...

Страница 5: ...ng the hardware provided HAND TIGHTEN Printed circuit board Brass washer Model TS51 Temperature Sensor Model TS52 Temperature Sensor Model TS52 Temperature Sensor Wiring Hub H32 Wiring Hub H32 SLP SLP...

Страница 6: ...the ER1 Electronic Receiver Module needs to be installed in the Wiring Hub Install Remote Wireless Sensors The TSER is wireless and powered by two AA batteries Two remote temperature sensors can be u...

Страница 7: ...2 Place the labels on the front of the thermostat over the battery cover The TSRC can be used to turn Econo Cooling ECool On of Off The TSRC can be wall mounted or can sit on a bedside table When the...

Страница 8: ...y Required when using dual fuel heat pumps TSER Sensor installed in Master Bedroom ER1 Electronic Receiver Module Inside Tu Day Upstairs Auto Downstairs Airflow HEAT Schedule AUTO FAN MENU MODE Heat S...

Страница 9: ...edroom See Note 2 Note 1 Note 2 Use one TS51 sensor for single sensor installations Use two TS52 sensors for dual sensor installations Number of wires used in cable Inside Tu Day Upstairs Auto Downsta...

Страница 10: ...ooling calls The equipment terminal can be designated as DS BK ODD or DHUM The Wiring Hub DS terminal is normally 24 VAC and goes to 0VAC when de humidification is active Option 42 turns de humidifica...

Страница 11: ...damper should open each hour based on ASHRAE 62 2 calculations and the damper size Factory Default OFF Range On or Off Factory Default 30 minutes Range 0 to 60 Option NEXT ENTER Option NEXT ENTER Sele...

Страница 12: ...ON to control Whole House Fan or Economizer using a 1 to 12 hour timer set in the thermostat by the homeowner using the User Menu The timer starts when the System is switched to ECool When the timer...

Страница 13: ...omizer Cooling Cooling Enable Free Cooling using Dampers and Equipment Fan Dampers and Fan controlled by Temperature Dampers and Fan Outdoor Temperature Limit Dampers and Fan Control by Timer Select O...

Страница 14: ...airs bedroom is too cold or too hot at night The Nighttime Airflow Control option directs more airflow to the sleeping area and less airflow to the unoccupied living area If the downstairs bedroom is...

Страница 15: ...t 2 Cool Wired temperature sensor for the sleep area Dual sensor installation Wireless temperature sensor for the sleep area Single or Dual sensor installation Requires ER1 Electronic receiver module...

Страница 16: ...rols product visit www fieldcontrols com Field Controls Technical Support 1 800 742 8368 fieldtec fieldcontrols com Phone 252 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC c Field...

Отзывы: