SYSTEM CONTROL KIT  

Model:

 CK-41P 

READ THE INSTALLATION INSTRUCTIONS CAREFULLY & COMPLETELY BEFORE BEGINNING THE INSTALLATION! 

Designed for use with the SWG Series Power Venter for controlling Natural 
Gas or L.P. Gas Appliances equipped with a 24V electric damper.  It is 
designed for modular connection to the appliance controls via the damper 
cable connection. 

I

TEMS INCLUDED IN KIT

 

1) Control box with mounted pressure switch, post purge timer and 

7” vent damper cable 

2) Flexible conduit connector 
1)  ¼” tubing connectors 

I

TEMS 

NOT 

INCLUDED IN KIT

 

• 

¼” O.D. aluminum, copper or stainless steel tubing 

• 

Junction box with connectors and additional circuit wiring, if 

required 

DO NOT DESTROY 

THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT 

 

WARNING:  

INSTALLER: IF THE APPLIANCE DOES NOT HAVE A BLOCKED VENT 

SWITCH, A GSK-3P SPILLAGE SWITCH KIT, P/N 46458600, (NOT INCLUDED) 
MUST BE INSTALLED (SEE DIAGRAM B).

 

Содержание 46457800

Страница 1: ...er cable connection ITEMS INCLUDED IN KIT 1 Control box with mounted pressure switch post purge timer and 7 vent damper cable 2 Flexible conduit connector 1 tubing connectors ITEMS NOT INCLUDED IN KIT O D aluminum copper or stainless steel tubing Junction box with connectors and additional circuit wiring if required DO NOT DESTROY THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT WARNING INSTALLER IF ...

Страница 2: ... control box if required using the supplied flexible conduit connector and approved connectors and anti short bushings PRESSURE SWITCH SENSING TUBE INSTALLATION 1 Attach the 1 4 inch tubing connector to the pressure tube on the SWG Venter See Fig 3 2 Connect installer supplied 1 4 O D aluminum copper or stainless steel tubing to the tubing connector 3 Route the tubing to the CK 41F junction box an...

Страница 3: ...nd B LOW VOLTAGE WIRING INSTRUCTIONS FOR BOILERS 1 Route the appliance s vent damper cable to the CK 41P Plug the cable into the receptacle located inside the CK 41P using the supplied plastic knockout grommet if the cable does not have a conduit connector See Diagram A 2 Connect the CK 41P s pre wired damper cable to the vent damper See Diagram A Snap the end of the flexible conduit into place on...

Страница 4: ...ther voltage the appliance is not calling for heat to the CK 41P If there is 24 volts continuously for at least 45 second there should be 115 volts from N to M If not the time relay is defective or L1 and N are not properly wired 2 Flue gas odor a Check system draft Adjust power venter s airflow adjustment damper if necessary b Check for negative pressure in building 3 Venter activates but burner ...

Страница 5: ... POST PURGE TIMER M TO 3 ON POST PURGE TIMER OTHERS PER HARNESS COLORS REPAIR AND REPLACEMENT PARTS LIST REPAIR AND REPLACEMENT PARTS LIST DESCRIPTION PART NUMBER Pressure Switch 46273100 Post Purge Timer 46282800 Wire Harness 46457200 ...

Страница 6: ..._______ INSTALLER S NAME _____________________________________________________ INSTALLER S COMPANY _________________________________________________ INSTALLER S PHONE NO ________________________________________________ DATE OF INSTALLATION _________________________________________________ CK 41P ...

Страница 7: ...Page 7 ...

Страница 8: ...Page 8 P N 46457800 Rev B 06 04 ...

Отзывы: