UV-AIRE™ AIR PURIFYING SYSTEM  

Model:

 UV-E 

(For use with 12”, 18” and 28” Field Controls Lamps) 

(120/240 volt application)

 

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION 

LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE 

AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE. 

DO NOT 

INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.

 

 

SAFETY CONSIDERATIONS 

WARNING:

  

Never expose eyes or skin to UVC light from any source. 

• 

Looking directly at the UVC light may cause permanent eye damage or blindness.  

• 

Never operate the UV-Aire™ Air Purifying System out of the plenum

WARNING:

 UV light will break down plastic materials not rated for UV exposure: 

(Examples: wire insulation, flex duct, drain pans and humidifiers) 

• 

The unit must be mounted at least 30” from the above stated type of materials.

 

• 

If it is necessary to mount the unit in direct line of site of these types of materials, they must be shielded 
with aluminum foil, aluminum foil tape, or sheet metal.

 

 

 

 

ITEMS INCLUDED IN KIT: 

1-UV-E power unit  (NEMA3 housing)
1-Mounting Template 
4-Sheet metal mounting screws 
1-Angled mounting bracket  
1-Flat mounting bracket 
1-Instruction Sheet 
1-Wing nut 
2-Hex nuts 
1-Lamp 

 

UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a 
homes’ heating and air conditioning system.  The treatment is a safe, silent, and proven way 
to make your home a healthier place to live. 

Содержание 46427300

Страница 1: ...the plenum WARNING UV light will break down plastic materials not rated for UV exposure Examples wire insulation flex duct drain pans and humidifiers The unit must be mounted at least 30 from the above stated type of materials If it is necessary to mount the unit in direct line of site of these types of materials they must be shielded with aluminum foil aluminum foil tape or sheet metal ITEMS INCL...

Страница 2: ...or death Never expose eyes or skin to direct UVC light from any source II INSTALLATION 1 Determine a suitable location on either the supply or return for the unit as shown in Figure 1 The unit must be mounted at least 3 feet from any flex duct type material NOTE Unit can only be mounted in a vertical position as noted on inside cover label 2 Apply mounting template to air duct as shown in Figure 2...

Страница 3: ...minal block Figure 5 12 Push power source wires through bushing in access cover then begin securing wires according to the wiring diagram in figure 8 See Figures 6 7 13 Replace access cover 14 Group wires together and tuck in wire clip on right side of box See Figure 9 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 WARNING Never expose eyes or skin to UVC light from any source Looking direc...

Страница 4: ... either be angled up and down or left to right depending upon duct design Figures A D NOTE Be sure to note location of lamp hole in bracket relative to unit base LAMP INSTALLATION This unit is listed for use with Field Controls lamps ONLY You will need to determine proper lamp selection based on duct size and desired configuration Refer to configuration table on page 6 of this manual 16 Remove tag...

Страница 5: ...make sure the wiring is correct and that the ballast is plugged in securely to lamp If lamp still does not glow contact technical support at 1 252 522 3031 for further assistance 23 After unit has been found to be working properly note date of installation on inside cover close cover and engage latch Apply supplied wire tie to latch or other locking mechanism to provide safety Figure 13 Figure 14 ...

Страница 6: ...OFFSET DIMENSIONS Lamp Length A B Lamp Part No 12 8 1 2 6 1 2 46365401 18 13 1 2 10 5 16 46365402 28 21 3 8 16 1 4 46365403 WARNING Never expose eyes or skin to UVC light from any source Looking directly at the UVC light may cause permanent eye damage or blindness Never operate the UV Aire Air Purifying System out of the plenum Avoid touching the glass portion of the lamp with your hands Standard ...

Страница 7: ...sal or recycling requirements According to the EPA s Universal Waste Rule these types of lamps may be disposed of into household waste 7 After replacing lamp make sure a new Lamp Replacement Label supplied with lamp replacement is applied to the housing and dated with the date of installation 8 Replace wire tie or locking mechanism to latch VI TROUBLESHOOTING GUIDE 1 If unit does not light up repl...

Страница 8: ... invoice price of products which prove to be defective in material or workmanship within a period of ninety days from date of purchase Field s obligation to repair or replace defective products or refund of invoice price constitutes agreed and liquidated damages for any breach of warranty by Field FIELD S LIABILITY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT ...