UV-AIRE™ AIR PURIFYING SYSTEM  

Model:

 UV-12,18 

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION 

LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE 

AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE. 

DO NOT 

INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.

 

 

SAFETY CONSIDERATIONS 

WARNING:

  

Never expose eyes or skin to UVC light from any source. 

• 

Looking directly at the UVC light may cause permanent eye damage or blindness.  

• 

Never operate the UV-Aire™ Air Purifying System out of the plenum

• 

Designed for a closed duct system. Do not mount near a supply or a return air opening 

• 

All duct openings in direct line of site of the UV light must be sealed with aluminum duct tape or equivalent 
sealing methods. 

WARNING:

 UV light will break down plastic materials not rated for UV exposure: 

(Examples: wire insulation, flex duct, drain pans and humidifiers) 

• 

The unit must be mounted at least 30” from the above stated type of materials.

 

• 

If it is necessary to mount the unit in direct line of site of these types of materials, they must be shielded 
with aluminum foil, aluminum foil tape, or sheet metal.

 

WARNING:

  DO NOT mount this unit outdoors. 

• 

This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). 

 

 

ITEMS INCLUDED IN KIT: 

1-UV-Aire

 power unit  

4-Sheet metal mounting screws 
1-Angled mounting bracket  
1-Flat mounting bracket 
1-Duct board mounting bracket 
1-Ultra Violet lamp 
1-Instruction Sheet 
1-Wing nut 
Caution Labels 
Gasket 

UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a 
homes’ heating and air conditioning system.  The treatment is a safe, silent, and proven way 
to make your home a healthier place to live. 

Содержание 46360900

Страница 1: ...hods WARNING UV light will break down plastic materials not rated for UV exposure Examples wire insulation flex duct drain pans and humidifiers The unit must be mounted at least 30 from the above stated type of materials If it is necessary to mount the unit in direct line of site of these types of materials they must be shielded with aluminum foil aluminum foil tape or sheet metal WARNING DO NOT m...

Страница 2: ...o not mount near a supply or a return air opening WARNING This product is designed for indoor installation only i e attics crawl spaces basements etc For use on gas fired oil fired electric and split system heat pump forced air systems This product is NOT designed to be mounted outside on gas fired or heat pump packaged units Split system heat pumps are systems where the air handler and the air co...

Страница 3: ...as shown in figure 4 c Using a knife or blade cut out a rectangle opening in the duct using the mounting plate as a template See Figure 5 d Remove the cut piece of duct See Figure 6 e Bend both tabs down and through duct at first bend point See Figures 7 8 f Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material See Figures 9 10 g Using a screwdriv...

Страница 4: ...g Bracket Specifications in section IV i Remove the two hex nuts and angled bracket from included bagged hardware ii Install the angled bracket and secure to the unit base with the hex nuts provided See Figure 14 NOTE Be sure to note location of lamp hole in bracket relative to unit base 6 Mount the unit base to the duct using the four mounting screws provided See Figure 15 7 Remove tag and alcoho...

Страница 5: ...ce any direct viewing of light See Figure 1 13 Press the power switch to the ON position Light on switch should be on indicating power 14 Look through view port in the box cover to be sure lamp is working You should see a blue glow The view port is covered with a plastic lens that blocks the UVC rays 15 If the lamp is not glowing follow steps 8 14 again If lamp still does not glow contact technica...

Страница 6: ...mine allowable clearances for proper mounting of the UV Aire unit on the duct LAMP OFFSET DIMENSIONS Unit Min Duct Size inches A B UV 12 9x12 8 1 2 6 1 2 UV 18 14x18 13 1 2 10 5 16 Standard 90 Installation Flat Bracket 16 Duct Patent Pending 45 Installation Single Lamp Angled Bracket 16 Duct UV Aire Configurations Chart B Good Best WARNING Never expose eyes or skin to UVC light from any source Loo...

Страница 7: ...r local waste management authority for local disposal or recycling requirements According to the EPA s Universal Waste Rule these types of lamps may be disposed of into household waste 6 Attach the ballast plug onto the end of the lamp 7 After replacing lamp make sure a new Lamp Replacement Label supplied with lamp replacement is applied to the housing and dated with the date of installation VII T...

Страница 8: ... invoice price of products which prove to be defective in material or workmanship within a period of ninety days from date of purchase Field s obligation to repair or replace defective products or refund of invoice price constitutes agreed and liquidated damages for any breach of warranty by Field FIELD S LIABILITY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT ...

Отзывы: