33
10.1.2 Sampling method
This method is used when the unit weight is not known. Procedures: -
1.
Apply samples with known quantity on weighing platform.
2.
Enter quantity through numeric keys and press
[@QTY]
.
3.
Calculation unit weight is then displayed on LCD3.
10.1.3 Employ the last unit weight when power on
To employ this function, set F35 = On. Under this setting the last unit weight (before powered off) will be
employed when powered on again.
To disable this function, set F35 to Off.
Note:
- Unit weight obtained by this function is not supported by Auto Unit Weight Enhancement Function
10.1.4 Recall unit weigh unit from quick PLU
Refer to paragraph
11.1.2
for details.
10.2 Start Counting Process
Once unit weight is entered (by either method listed on paragraph
10.1
, instrument is ready for counting
operation. By adding more to or removing some from weighing platform, the corresponding quantity will be
displayed on LCD1.
10.3 Auto Unit Weight Enhancement Function
In order to obtain the best counting result and minimize sampling error, this instrument is equipped with Auto
Unit Weight Enhancement Function. This function will be employed when unit weight is determined by sampling
method
7
.
Auto Unit Weight Enhancement Function starts when
all
the below are met: -
a.
Unit weight is obtained by sampling method as listed on
10.1.2
.
b.
6 pieces
≦
quantity
added
≦
9999 pieces.
c.
6 pieces
≦
quantity
added
≦
100% of last total quantity on weighing platform.
Note
: - Auto Unit Weight Enhancement Function stops when total quantity on weighing platform
reaches 10000 pieces or more.
When all the above requirements are met, a new unit weight will be calculated and displayed on LCD3.
10.4 Check Function
8
9
10
Check function is used to compare current weighing or counting result with the preset Lo and Hi Limit. The
comparison results (Lo, OK, Hi) will then be displayed in different backlight colors with or without buzzer
11
.
7
Refer to
paragraph
10.1.2
for details.
8
Check mode will not operate when weight is less than 20d (or 20d1 for dual weighing range/interval mode).
9
Set also F15 for desired Check buzzer output.
10
If necessary, set F26 to meeting operation requirements.
11
Set F15 for preferred buzzer output configuration.