background image

 

 

QUICK START GUIDE

 

 

Fidelis Network® Collector SA

 

 

www.fidelissecurity.com

 

©Fidelis Cybersecurity

 

 

4. Collector SA Networking Environment 

The Collector SA appliances use the Admin network for service and inter-node communication. The 

appliances also offer the IPMI/iLO interface for optional out-of-band management of the appliance.  
Use the tables below to identify the count and type of switch ports necessary to support the number 

of appliances for your deployment.  

Admin Network 

The Admin network connects the Collector SA to the Fidelis Network sensors and CommandPost/K2 

systems. 

Appliance 

Switch Port Type 

Qty. 

Collector SA 

GbE - RJ45/Cat5+ (copper twisted pair) 

iLO / IPMI Network 

Optional network for remote/out-of-band server administration. 

Appliance 

Switch Port Type 

Qty. 

Collector SA 

GbE - RJ45/Cat5+ (copper twisted pair) 

5. Appliance — Logical Network Configuration 

Each physical connection must be assigned logical network information. Build a table of the logical 

information for each appliance that you can reference during configuration

Appendix A 

has a 

worksheet you can use to build your own Network Configuration table that you will reference multiple 

times during setup. 

Sample Network Configuration Table 

Network Setting 

Assignments 

Interface: 

Admin/eth0 

iLO/IMM 

Hostname (FQDN) 

CollectorSA-1.organization.net. 

Static IP Address 

10.1.2.3 

10.2.3.4 

Subnet Mask 

255.255.255.0 

255.255.255.0 

Gateway 

10.1.2.1 

 

Proxy Server 

10.5.6.7 

DNS Servers 

8.8.4.4, 8.8.8.8 

NTP Servers 

0.pool1.ntp.org. 

Time Zone 

UTC (+0) 

Содержание Network Collector SA Rev-1 Series

Страница 1: ...www fidelissecurity com QUICK START GUIDE Fidelis Network Collector SA Rev I Collector SA Appliances Based on HP DL360 G10 Platforms...

Страница 2: ...ions can be found at https support fidelissecurity com or through the icon in the CommandPost K2 user interface Appliance Default Passwords System Account Default Password SSH Appliance Console fideli...

Страница 3: ...3 Network switches with enough physical ports Section 4 Logical network information IP addresses hostnames Section 5 Appendix A For Fidelis Network Software version 9 0 5 and later the appliance syste...

Страница 4: ...ed pair 1 iLO IPMI Network Optional network for remote out of band server administration Appliance Switch Port Type Qty Collector SA GbE RJ45 Cat5 copper twisted pair 1 5 Appliance Logical Network Con...

Страница 5: ...es described in sections 3 and 4 begin to connect the appliances to the networks To cable the Collector SA appliance s to the switches 1 Connect Admin eth0 port to the Admin switch port 2 Connect the...

Страница 6: ...attach an Ethernet cable from a client system such as a laptop to the Admin eth0 port on the appliance The default IP address is 192 168 42 11 24 Assign a static IP from the same subnet to the networ...

Страница 7: ...ce Description optional Specify a description for example location business unit etc 5 Click Save 6 Register the Collector to CommandPost K2 Click Register and accept the End User License Agreement EU...

Страница 8: ...nd Resources Rev I Collector SA Rev I Form Factor 1U rack mount chassis SFF CPU Dual Intel Xeon Gold 6136 12 24 core 3 0 Ghz Memory 192 GB ECC DDR4 2666Mhz Storage Capacity Configuration 480GB 2x SSD...

Страница 9: ...low shows the software to apply based on the appliance SKU You can find the SKU in the following locations Note that the SKU typically starts with FSS or FNH Appliance lid UID decal see sample on righ...

Отзывы: