![FIBRO 2480.00.32.71 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/fibro/2480-00-32-71/2480-00-32-71_instruction-manual_2286894019.webp)
Instructions manual Nitrogen Compact Booster
19/38
Assembly
5.3
Assembling the machine
WARNING!
High pressure
Unsuitable tools may fail. This means that nitrogen can escape under high pressure.
Only use additional equipment such as filling and control fitting, filling hose and bottle pres-
sure regulator . Risk of injury
The following description considers the assembly of all required parts and all possible additional
equipment.
1. Hang the machine over the connection of the nitrogen bottle.
2. Bottle hose to be connected.
a) Remove yellow protective cap.
b) Connect the connection screws of the bottle hose to the nitrogen bottle. ATTENTION
left-handed thread
c) Tighten the nut with a spanner.
3. Pressurised air adapter to be screwed into the pressurised air inlet.
a) pressurised air inlet at the filter and control valve, thread G 1/4".
b) Remove yellow protective cap.
c) Screw company specific pressurised air adapter with seal into the pressurised air inlet.
2.
1.
3.