The copyright of this document is owned by Fibocom Wireless Inc., and the document shall not be replicated without approval.
SC806Hardware User ManualPage56 of 70
9.2
Charge Parameters
Table39Charge parameters
Parameter
Min
Nominal
Max
Unit
Trickle Charge - A Current
81
90
99
mA
Trickle Charge - A threshold voltage (15.62mV Stepping)
2.5
2.796
2.984
V
Trickle Charge - B threshold voltage (18.75mV Stepping)
3.0
3.2
3.581
V
Charge voltage setting range (25mV stepping)
4
4.2
4.775
V
Charge voltage accuracy
/
/
+/-2
%
Charge current setting range (90mA stepping)
90
/
1440
mA
Charge current accuracy
/
/
+/-10
%
Charge cut-off current: when the charge current is set to
90mA to 450mA
/
7
/
%
Charge cut-off current: when the charge current is set to
450mA to 1440mA
/
7.4
/
%
9.3
Operating Current
Table40Operating current
Parameter
Description
Condition
Result
Unit
Ioff
Power Off
Power Off
10
uA
Isleep
WCDMA
DRX=8
3.44
mA
FDD LTE
DPC(DefaultPaging Cycle)=#256
2.33
Radio Off
AT+CFUN=4 Flight Mode
1.66