Locating the site features and zone boundaries
Page 78
FiberPatrol IDS Software Guide
Tap the cable one fence panel away from the service loop(s) at gate locations, where the gate will
be included as part of a zone.
At bypass locations
Tap the cable two fence panels away from each isolation loop at bypass locations. Record the
location results for both sides of the obstacle. Measure back to the obstacle and add, or subtract,
10 m for each isolation loop. Enter the calculated values as the bypass start and end locations.
At locations of non-linear cable deployment
Tap the cable at the fence posts adjacent to the non-linear deployment.
Figure 87 Tap test location - gate (part of zone)
Figure 88 Tap test location - bypassed obstacles
Figure 89 Tap test location - non-linear cable deployment
tap cable 1 panel away from service loop
loop
service
loop
service
tap cable 1 panel away from service loop
tap cable 2 panels away
isolation
loop
isolation
loop
from the bypassed obstacle
tap cable 2 panels away
from the bypassed obstacle
tap cable at post adjacent to non-linear deployment
tap cable at post adjacent to non-linear deployment
heavy gauge tension post
diagonal brace support
heavy gauge tension post