11
4: InstallatIon
3. Verify correctness of connection.
4. Power the device.
5. Add the device to the Z-Wave network.
4.5: Connection with 2-wire 0-10V sensor
The 2-wire analog sensor requires pull-up resistor.
You can connect up to 2 analog sensors to IN1/IN2 terminals.
The 12V supply is required for these type of sensors.
1. Disconnect power.
2. Connect with the diagram below:
GND
IN2
ANALOG OUT
GND
P
1
GND 12V
Diagram 5: Example connection with 2-wire analog sensor to
IN2 input
(1 – 2-wire analog sensor)
3. Verify correctness of connection.
4. Power the device.
5. Add the device to the Z-Wave network.
6. Change values of parameters:
• Connected to IN1: change parameter 20 to 5
• Connected to IN2: change parameter 21 to 5
4.6: Connection with 3-wire 0-10V sensor
You can connect up to 2 analog sensors IN1/IN2 terminals.
1. Disconnect power.
2. Connect with the diagram below:
GND
IN1
P
VDD
ANALOG OUT
GND
1
GND 9-30V
Diagram 6: Example connection with 3-wire analog sensor to
IN1 input
(1 – 3-wire analog sensor)