FIBARO ROLLER SHUTTER 3 Скачать руководство пользователя страница 1

  

 

Fibaro  

Roller Shutter 3  

SKU: FIBEFGR-223  

 
 
 

Quickstart 

This is a 

secure Roller Shutter 

for 

Europe

. To run this device please connect it to your mains 

power supply. To add this device to your network execute the following action:  
Quickly, triple click the S1 switch.  

 

Important safety information 

Please read this manual carefully. Failure to follow the recommendations in this manual may be 
dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be 
liable for any loss or damage resulting from failure to comply with the instructions in this manual 
or any other material. Use this equipment only for its intended purpose. Follow the disposal 
instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat 
sources.  

What is Z-Wave? 

Z-Wave is the international wireless protocol for communication in the Smart Home. This device 
is suited for use in the region mentioned in the Quickstart section.  

Содержание ROLLER SHUTTER 3

Страница 1: ...l may be dangerous or may violate the law The manufacturer importer distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material Use this equipment only for its intended purpose Follow the disposal instructions Do not dispose of electronic equipment or batteries in a fire or near open heat sources What...

Страница 2: ...blinds awnings venetian blinds gates and other single phase AC powered devices Roller Shutter 3 allows precise positioning of roller blinds or venetian blind lamellas The device is equipped with power and energy monitoring It allows to control connected devices either via the Z Wave network or via a switch connected directly to it Prepare for Installation Reset Please read the user manual before i...

Страница 3: ...cians under consideration of the country specific installation guidelines norms may do works with mains power Prior to the assembly of the product the voltage network has to be switched off and ensured against re switching Installation Installation with standard blinds Notes for the diagrams S1 terminal for 1st switch used to add remove the device S2 terminal for 2nd switch Q2 2nd output terminal ...

Страница 4: ...ver may be performed only by certified professionals The motor must be equipped with the appropriate limit switches It is recommended to connect a NC normally closed contact of an IR barrier to S2 terminal Opening the contact will stop the gate In addition it is recommended to connect an emergency stop button to the motors neutral N wire In emergency pushing the emergency stop button will cut the ...

Страница 5: ...e consists of an automatic full movement between the limit switches up down and up again Note If you notice the calibration process fail e g it does not start movement times are really short or highly inaccurate adjust parameter 155 value e g reduce it by half Standard roller blind positioning Calibration using a connected momentary switch 1 Make sure o the device is supplied o the momentary switc...

Страница 6: ...elease and click the B button again 5 The device will perform the calibration process completing full cycle up down and up again 6 Test whether the positioning works correctly Calibration using parameter 1 Make sure o the device is supplied o the device added to the Z Wave network o parameter 151 is set to 1 or 2 2 Set the parameter 150 value to 2 3 The device will perform the calibration process ...

Страница 7: ...ler blinds between extreme positions by clicking UP or DOWN switch o If roller blind stops before reaching top increase the value of parameter 155 o If roller blind does not stop after reaching top decrease the value of parameter 155 o If roller blind stops before reaching bottom increase the value of parameter 156 o If roller blind does not stop after reaching bottom decrease value of parameter 1...

Страница 8: ...lick the B button Note Communication mode of the device may switch between direct and one using routing especially if the device is on the limit of the direct range Z Wave range tester signaling modes Visual indicator pulsing green the device attempts to establish a direct communication with the main controller If a direct communication attempt fails the device will try to establish a routed commu...

Страница 9: ...hints for network installation if things dont work as expected 1 Make sure a device is in factory reset state before including In doubt exclude before include 2 If inclusion still fails check if both devices use the same frequency 3 Remove all dead devices from associations Otherwise you will see severe delays 4 Never use sleeping battery devices without a central controller 5 Dont poll FLIRS devi...

Страница 10: ...es greater than 32768 may needed to be given as negative values too Parameter 20 Switch type This parameter defines as what type the device should treat the switch connected to the S1 and S2 terminals This parameter is not relevant in gate operating modes parameter 151 set to 3 or 4 In this case switch always works as a momentary and has to be connected to S1 terminal Size 1 Byte Default Value 2 S...

Страница 11: ...ce should react The parameters consist of 4 bytes three most significant bytes are set according to the official Z Wave protocol specification For a setting of this parameter please refer to the manufacturer s manual Size 4 Byte Default Value Setting Description Parameter 32 Alarm configuration 3rd slot Smoke This parameter determines to which alarm frames and how the device should react The param...

Страница 12: ...ctions result in sending scene IDs assigned to them Size 1 Byte Default Value 0 Setting Description 1 Key pressed 1 time 2 Key pressed 2 times 4 Key pressed 3 times 8 Key hold down and key released 15 All Parameter 42 S2 switch scenes sent This parameter determines which actions result in sending scene IDs assigned to them Size 1 Byte Default Value 0 Setting Description 1 Key pressed 1 time 2 Key ...

Страница 13: ...c power reports are sent to the main controller Periodic reports do not depend on power change parameter 61 Size 2 Byte Default Value 3600 Setting Description 0 periodic reports are disabled 30 32400 report interval in seconds Parameter 65 Energy reports on change This parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller Si...

Страница 14: ...oning 2 Venetian blind with positioning 3 gate without positioning 4 gate with positioning 5 roller blind with built in driver 6 roller blind with built in driver impulse Parameter 152 Venetian blind time of full turn of the slats For Venetian blinds parameter 151 set to 2 the parameter determines time of full turn cycle of the slats For gates parameter 151 set to 3 or 4 the parameter determines t...

Страница 15: ...or will be stopped after end switch contacts are closed For gates parameter 151 set to 3 or 4 the parameter determines the time after which the gate will start closing automatically if S2 contacts are opened if set to 0 gate will not close Size 2 Byte Default Value 10 Setting Description 0 60 0 60s time Parameter 155 Motor operation detection Power threshold to be interpreted as reaching a limit s...

Страница 16: ... EAN 5905279987197 IP Class IP 20 Voltage 230 V Load 1 7 A Device Type Roller Shutter Generic Device Class Multilevel Switch Specific Device Class Motor Control Device B Firmware Version 05 00 Z Wave Version 06 02 Z Wave Product Id 0x010f 0x0303 0x1000 Frequency Europe 868 4 Mhz Maximum transmission power 5 mW Supported Command Classes Basic Application Status Switch Multilevel Meter Crc 16 Encap ...

Страница 17: ...primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Informatio...

Отзывы: