FIBARO FGS-221-EN-A-v1.00 Скачать руководство пользователя страница 1

OPERATING MANUAL

DOUBLE RELAY SWITCH 

FGS-221-EN-A-v1.00

ENG

Remotely Controlled Double Relay Switch of FIBARO system is 

designed to operate in a wall switch box or in locations where the 

control of an electric device (up to 1.5kW) is needed. It is also 

possible to send a signal to any system that is to be integrated with 

Fibaro system.

• Controlled by FIBARO system devices or any Z-Wave controller.
• Microprocessor control
• Executive elements: relays.
• The device may be operated by mono-stable and bi-stable 
push-buttons.

* In case of load other than resistive, pay attention to the value of    

cosᵠ and if necessary apply load lower than the rated load.

Specifications

Power supply: 

Maximum load current for 

single AC output: 

Maximum load current for 

single DC output:

Output circuit power

(resistive load-230V):

 

Comply with EU standards:

Circuit temperature limits: 

Operational temperature:

For installation in boxes:

Radio protocol: 

Radio Frequency:

Range:

Dimensions (L x W x H): 

Electricity consumption: 

110 - 230 V AC ±10% 50/60Hz

24-60V DC ±10%

8A / 230V 50/60Hz

8A / 30V 

2 x 1.5 kW

EN 55015 

EN 60669-2-1 

105 °C 

0 - 40 °C 

Ø ≥ 50mm

Z-Wave

868,4 MHz for EU; 

908,4 MHz for US; 

921,4 MHz for AUS/NZ/BRA

up to 50 m outdoors

up to 30 m indoors

(depending on building materials)

42 x 37 x 17 mm

< 0,8W

Technical Information

DANGER

Danger of electrocution! All works on the device 

may be performed only by a qualified and licensed 

electrician. Observe national regulations.

DANGER

Danger of electrocution. Even when the device is 

turned off, voltage may be present at its terminals. 

Any works introducing changes into the 

configuration of connections or the load must be 

always performed with disconnected voltage 

(disable the fuse).

TIPS

•  Do not connect the device to loads exceeding 

recommended values. 
•  Connect only in accordance with the diagram 

presented in the manual. Improper connections may 

be dangerous.

i

FIBARO is a wireless system, based on Z-Wave technology. 

FIBARO provides many advantages when compared to similar 

systems. In general, radio systems create a direct connection 

between the receiver and transmitter. But the radio signal is 

weakened by various obstacles located on its path (apartment walls, 

furniture, etc.) and in extreme cases it fails to transfer required data. 

The advantage of FIBARO system is that its devices apart from 

being transmitters and receivers of signals, they are also a signal 

"duplicators". When a direct connection path between the transmitter 

and the receiver can not be established, the connection may be 

achieved through other intermediate devices.

FIBARO is a bi-directional wireless system. It means that the signal 

is not only sent to the receivers but also the receivers send the 

confirmation of its reception. This operation confirms their status so 

to check whether they are active. Safety of the FIBARO system 

transmission is comparable to the safety of transmission in data bus 

wired systems. 

FIBARO operates in the free band for data transmission. The 

frequency depends on radio regulations in individual country . Each 

FIBARO network has its own unique network identification number 

(home ID), which is why it is possible to co-operate two or more 

independent systems in a single building without any interference.

Although Z-Wave is quite new technology, it has already become 

recognizable and officially binding standard, similarly to Wi-Fi. Many 

manufacturers in various industries offer solutions based on Z-Wave 

technology, guaranteeing their compatibility. This means that the 

system is open and it may be extended in the future. Find more 

information at www.fibaro.com.

FIBARO generates a dynamic network structure. After FIBARO 

system is switched on, the location of its individual components is 

automatically updated in real-time through status confirmation 

signals received from devices operating in a "mesh" network.

The In-Wall Double Relay Switch is hereinafter referred to as Fibaro 

Switch. It is designed to switch on/off devices connected to its 

terminals using radio waves, controllers and a push button directly 

connected to Fibaro Switch. 

Danger of electrocution.

II Assembling Double Relay Switch

1. Before installation ensure that the voltage supply is 

disconnected.

2. Connect Double Relay Switch as shown on the diagram

3. Place the switch in the electrical box 

4. Arrange the antenna (tips are presented below diagrams)

I GENERAL INFORMATION ABOUT FIBARO SYSTEM

Note! 

It is possible to supply the load with voltage other 

than the power supply to Double Relay Switch (e.g. 

different phase or voltage or even DC. Detailed data 

are contained in specifications and diagrams of 

Figure 1).

i

Note! 

It should be noted that only the push-button 

connected to S1 terminal and service push-button B 

enables "learning" mode (Include/ Exclude).  

i

Parameter no. 1 - Activate / deactivate functions ALL ON / ALL 

OFF. 

 default value 255

Available configuration parameters:

255

 - ALL ON active, ALL OFF active.

0

 - ALL ON is not active ALL OFF is not active

1

 - ALL ON is not active ALL OFF active

2

 - ALL ON active ALL OFF is not active

Parameter no. 3 -  Automatic turning off relay after set time 

 

default value 0

Available configuration parameters:

0

 - Auto OFF disabled for both relays 

1

 - Auto OFF enabled for relay no. 1. disabled for relay no. 2.

2

 - Auto OFF disabled for relay no. 1. enabled for relay no. 2.

3

 - Auto OFF enabled for both relays

Parameter no. 4 - Time after witch relay is automatically

 

turned 

off.

default value 20  (200ms)

Available configuration parameters:

[1- 255] (10ms – 2,5s)

 time after relay is automatically turned off.

Parameter no. 5 – Time after witch relay no. 2 is automatically 

turned off. 

default value 20 (200ms)

Available configuration parameters:

[1- 255] (10ms – 2,5s)

 time after relay is automatically turned off.

Parameter no. 6 - Sending commands to control  devices 

assigned to 1-st association group (key no. 1) 

default value 0

Available configuration parameters:

0 commands are sent when device is turned on and off

1 commands are sent when device is turned off. Enabling device 

does not send control commands. Double-clicking key sends 'turn 

on' command, dimmers memorize the last saved state (e.g. 50% 

brightness).

2 commands are sent when device is turned off. Enabling device 

does not send control commands. Double-clicking key sends 'turn 

on' command and dimmers are set to 100% brightness.

NOTE: Parameter 15 value must be set to 1 to work properly. This 

activates the double-click functionality - dimmer/roller shutter control.

Parameter no. 7 – Sending commands to control  devices 

assigned to 2-nd association group (key no. 2)

default value 0

Available configuration parameters:

0 commands are sent when device is turned on and off

1 commands are sent when device is turned off. Enabling device 

does not send control commands. Double-clicking key sends 'turn 

on' command, dimmers memorize the last saved state (e.g. 50% 

brightness).

2 commands are sent when device is turned off. Enabling device 

does not send control commands. Double-clicking key sends 'turn 

on' command and dimmers are set to 100% brightness.

Info: Parameter 15 must be set to 1 to make this parameter work 

properly. This activates the double-click functionality - dimmer/roller 

shutter control.

Parameter no. 13 - Assigns bistable key status to the device 

status.

 default value 0

Available configuration parameters:

0 [On / Off] device changes status on key status change.

1 Device status depends on key status: ON when the key is ON, OFF 

when the key is OFF.

Info: Remote control from Fibaro System Is Still Possible. This 

function is useful When you want display status of external devices, 

e.g. Motion Sensor, in Fibaro System.

Parameter no. 14 - Switch type connector, you may choose 

between mono-stable and bi-stable switches. 

default value 1

Options for changing the parameter:

0

 - mono-stable switch

1

 - bi-stable switch

single switch

single switch

- option with an alternative power supply for the load

double switch

Durability of the device depends on applied load. For 

resistive load (light bulbs, etc.) and 8A current, the 

durability exceeds 200 000 switches. For inductive 

load,  e.g.  fluorescent  lamp  with  cosᵠ  =  0.6  the 

flowing current should be limited to approx. 6A to 

ensure reliable operation of the device for similar 

long period.

i

double switch

 - option with an alternative power supply for the load

NOTES FOR THE DIAGRAM:

N - terminal for neutral lead

L - terminal for  live lead

I - input terminal for load power supply

O1 i O2 - output terminal of the load

S2 - terminal for key no. 2 

S1 – terminal for key no. 1 (has the option of entering the device in 

learning mode)    

B- service button (used to add or remove a device from the system)

Fig.1 Circuit diagrams for Double Relay Switch.

Locate the antenna as far from metal elements as 

possible (connecting wires, bracket rings, etc.) in 

order to  prevent interferences. 

i

Metal surfaces in the direct vicinity of the antenna 

(e.g. flush mounted metal boxes, metal door frames) 

may impair signal reception! 

i

Do not cut or shorten the antenna - its length is 

perfectly matched to the band in which the system 

operates

i

TIPS FOR ARRANGING THE ANTENNA:

DICTIONARY: 

                                                                                                                               

• INCLUSION (Adding) 

- a device sends "Node Info" frame, to 

enable user to add it to Fibaro system (Home Center)

• EXCLUSION (Removing) 

- removing a device from the Fibaro 

radio system

• ASSOCIATION 

- controlling other devices of Fibaro system

• MultiChannelAssociation 

- controlling other multichannel devices 

of Fibaro system 

III Activating Double Relay Switch

1. Installing the Double Relay Switch

STEP 1

 

Connect the device in accordance with the circuit diagram presented 

in Figure 1. Switch on 230V of the mains voltage.

[Adding/ Removing] Double Relay Switch [to/ from] Z-wave 

network

STEP 2

 

Double Relay Switch must be placed within the range of Home 

Center controller, as adding mode requires direct communication 

with the controller.

  

STEP 3

 

Find key no. 1 which allows to switch circuit 1 on, in accordance with 

the diagram 

STEP 4

  

Set the Home Center controller in add/remove mode (see the 

controller's manual)

STEP 5

  

Add Double Relay Switch to the network by pushing three times key 

no. or push-button B located inside the housing of the device. For 

bi-stable switch perform 3 position changes.

WARNING!

 

Double Relay Switch cancels the "learning" mode 

after key no. 1 is pressed once. Therefore, pressing 

key no. 1 four times will not add the devices to the 

network. The same applies to push-button B.

i

WARNING!

 

Double Relay Switch is set by default to operate with 

mono-stable switches (i.e. single-pole switch or bell 

switch). While adding Double Relay Switch to the 

network with bi-stable switches, ensure that all 

switch contacts are open (off), because closing them 

results in activating the push-button and this will 

prevent adding the device to the network. 

i

During the installation it is recommended to use a 

mono-stable keys or push- button B.

STEP 6

 

The controller indicates when the device is correctly added to the 

network, (see the manual of Home Center controller).

2. Resetting Double Relay Switch

Fibaro Switch provides three  methods for resetting.

Method I : 

Reset by removing  Double Relay Switch from the 

existing Z-Wave network.  The device may be removed using the 

controller that has the ability to include/exclude devices from/to 

Z-Wave network (see the manual of controller).

Method II

 : Within 5 sec. after connecting mains voltage supply 

Double Relay Switch allows the user to reset settings by single 

pressing S1 key and then holding key S2  

Method III

 : Reset by holding B button for 3 sec. after connecting 

mains voltage to the Switch

3. Controlling Double Relay Switch by mono-stable 

or bi-stable switches.

Mono-stable switch (after releasing the push-button a spring 

automatically pushes back  and disconnects the button )

- Turning on/off circuit 1 or 2 - briefly press the push-button 

corresponding to a chosen circuit (see diagram). 

Bi-stable switch (operates as a two-position switch, it has no 

spring that would push back the device after releasing manual 

pressure)

- Turning on/off the circuit - change the position of selected 

push-button from the current position.

4. Controlling Double Relay Switch using a 

command: ALL ON / ALL OFF

Double Relay Switch responds to commands ALL ON / ALL OFF that 

may be sent by the controller. ALL ON / ALL OFF commands are 

usually implemented in Z-Wave remote control.

By default, Double Relay Switch accepts both active commands ALL 

ON and ALL OFF. Settings may be changed by entering an 

appropriate value into configuration register no. 1 (see configuration)

5. Controlling Double Relay Switch using Home 

Center controller

 

After adding Double Fibaro Switch to the network, it will be 

represented in Home Center by the following two icons (one icon 

represents one channel):

Turning on/off  the device connected to Double Relay Switch is 

performed by pressing ON/OFF icon.

Association enables Fibaro Switch to directly control a device 

included in Z-Wave network e.g. Dimmer, Switch (ON-OFF), Roller 

Shutter or scene (scene may be controlled only through the Home 

Center controller).

Fig. 2 Icon  of 

Double Relay Switch

 shown by Home Center 

controller

IV Association 

WARNING! 

Association ensures direct transfer of control 

commands between devices, and is performed 

without participation of the main controller.

i

Fibaro Switch provides association of three groups.

1st group is assigned to key no. 1

2nd group is assigned to key no. 2

3rd group  reports state of devices. Only one device can be 

associated to this group.

Fibaro Switch enables user to control up to 16 normal devices, and 7 

MultiChannel devices in group no. 1 and no. 2, group no. 3 has only 

one field. The first field in each group is reserved for the network 

controller. It is recommended to use up to 10 devices, as the time 

required by the device to send a command to each associated 

device may be quite long.

To add an association (using the Home Center controller), go to

device options by clicking the following icon:

Select the "device options" tab. Then specify to which group and 

what devices are to be associated. Sending relevant information to 

devices added to associated groups may take even a few minutes. 

WARNING! 

When Fibaro Switch sends control commands and    

a new command is issued, then the current one 

command transmission is interrupted to send new 

commands. 

i

 FGS221 Fibaro Switch  supports the operation of multi-channel 

devices.  Multichannel devices are devices that include two or more 

circuits inside one physical unit. 

The following settings are available in the Fibaro interface as simple 

options that may be chosen by selecting the appropriate box

In order to configure Fibaro Switch (using the Home Center 

controller), go to device options by clicking the following icon: 

 

V Configuration

SWITCH

L N

S1 S2

O2O1 I

L

N

B

SWITCH

L N

S1 S2

O2 O1 I

L
N

B

alternative 

power 

supply

SWITCH

L N

S1 S2

O2 O1 I

L
N

B

SWITCH

L N

S1

O2 O1 I

S2

L

N

B

alternative 

power 

supply

FGS221 Double  Relay Switch is a multichannel device. It means 

that it has two independent executive circuits - each circuit is 

recognized by the Home Center controller as a separate device. 

Accordingly, each channel is represented by an independent icon. 

The first channel is operated by a push-button connected to S1 

terminal and it is the main (default) channel. 

The association of the second channel of the double relay switch 

may be operated only by devices supporting multi-channel 

association !

Отзывы: