FIBARO FGK-10 Series Скачать руководство пользователя страница 1

FIBARO DOOR/WINDOW SENSOR

FGK-10x

CONTENTS

#1: Description and features 

4

#2: Basic activation 

5

#3: Adding/removing the device 

6

#4: Temperature sensor 

7

#5: Button or external sensor 

8

#6: Physical installation 

9

#7: Operating the device 

10

#8: Association 

12

#9: Advanced parameters 

13

#10: Specifications 

19

#11: Regulations 

20

O P E R A T I N G

M A N U A L

EN

v2.0

Содержание FGK-10 Series

Страница 1: ... Basic activation 5 3 Adding removing the device 6 4 Temperature sensor 7 5 Button or external sensor 8 6 Physical installation 9 7 Operating the device 10 8 Association 12 9 Advanced parameters 13 10 Specifications 19 11 Regulations 20 O P E R A T I N G M A N U A L EN v2 0 ...

Страница 2: ......

Страница 3: ...ices are not only receivers but can also repeat the signal increasing the Z Wave network s range It gives advantage over traditional wireless systems that require direct link between transmitter and receiver as a result the construction of the building could affect network s range negatively Every Z Wave network has its unique identification number home ID Multiple independent networks can exist i...

Страница 4: ...ce s status will automatically send signal to the Z Wave controller and associated devices Sensor can be used to trigger scenes and everywhere there is a need for information about opening or closing of doors windows garage doors etc Opening is detected by separating the sensor s body and the magnet In addition the FIBARO Door Window Sensor supports one DS18B20 temperature sensor and has one poten...

Страница 5: ...evice on page 6 5 Install the device see Physical installation on page 9 NOTE The antenna should be placed above the battery Never cut shorten or bend the antenna Its length is suited to the band at which the system op erates i NOTE Metal surfaces in close vicinity e g metal switch boxes metal door trims may im pair the reception ca pability i ...

Страница 6: ...earning mode allowing to remove the device from existing Z Wave network To remove the device from the Z Wave network 1 Close the cover 2 Place the Door Window Sensor within the direct range of your Z Wave controller 3 Set the main controller into remove mode see the controller s manual 4 Quickly three times press the TMP button 5 Wait for the removing process to end 6 Successful removing will be c...

Страница 7: ...may be installed in humid conditions under water sealed in concrete or placed under the floor CAUTION Connecting devic es and sensors other than DS18B20 is not allowed To activate the device with temperature measurement functionality 1 Open the cover 2 Connect the temperature sensor to terminals of the device according to the diagram 3 Add the device see Adding removing the device on page 6 4 Inst...

Страница 8: ...iagram 3 Add the device see Adding removing the device on page 6 if the device is not already added 4 In case of connecting external sensor modify advanced parameter no 20 to match type of the sensor then remove and re add the device to the network 5 Install the device see Physical installation on page 9 IN GND MOMENTARY SWITCH TOP VIEW TMP GND GROUND ground terminal IN potential free input NOTE P...

Страница 9: ... bottom of the device and magnet 2 Peel off the protective layer of the sticker 3 Stick the device onto the door window frame 4 Stick the magnet onto the moving part of the door window no further than 5mm from the sensor max 5 mm Correct postioning of the magnet in relation to the Sensor Positioning of the Sensor and the magnet ...

Страница 10: ... sensor the additional temperature sensor icon will be displayed Tamper TMP button The Door Window Sensor is equipped with a tamper switch with two buttons First TMP button is located inside the device pressed by the closed cover Second TMP button is located at bottom of the device pressed by the surface on which the device is mounted For the tamper switch to work one of the buttons must always be...

Страница 11: ...e pro cedure of removing described in Adding removing the device on page 6 i Waking up the Door Window Sensor The Door Window Sensor needs to be woken up to receive informa tion about the new configuration from the controller like parameters and associations To wake up the sensor manually click one of the TMP buttons while the other button is pressed Replacing the battery Life of the battery inclu...

Страница 12: ... options by clicking the icon 2 Select the Advanced tab 3 Specify to which group and what devices are to be associated 4 Wait for the configuration process to end Sending relevant infor mation to devices added to associated groups may take even a few minutes 5 Wake up the device manually to speed up the configuration process NOTE Association allows di rect transfer of control commands between devi...

Страница 13: ...ndow closed 1 door window opened Default setting 0 Parameter size 1 byte Wake up interval Available settings 0 or 3600 64800 in seconds 1h 18h Default setting 21 600 every 6 hours The Door Window Sensor will wake up after each defined time inter val and always try to connect with the main controller After a suc cessful communication attempt the sensor will update configuration parameters associati...

Страница 14: ...ernately to switch the devices on and off Commands repre sent the values of BASIC SET command frames Parameter is inactive in external button mode parameter 1 set to 1 Available settings 0 switch after opening and closing 1 switch after opening 2 switch after closing Default setting 0 Parameter size 1 byte 11 Commands sent to 2nd association group Command frames sent to devices added to the 2nd as...

Страница 15: ...nal sensor is connected to IN input it is possible to choose its functionality Otherwise it is recommended to set this parameter to default value Available settings 0 Door Window Sensor General Purpose Alarm 1 smoke sensor Smoke Alarm 2 CO detector CO Alarm 3 CO2 detector CO2 Alarm 4 high temperature sensor Heat Alarm 5 flood sensor Water Alarm Default setting 0 Parameter size 1 byte 30 Delay of t...

Страница 16: ... Default setting 0 Parameter size 2 bytes 53 Temperature offset The value to be added to the actual temperature measured by the sen sor temperature compensation Available settings 1000 1000 100 100 C 0 1 C step Default setting 0 0 C Parameter size 4 bytes 54 Temperature alarm reports Temperature alarms reported to the Z Wave controller Thresholds are set in parameters 55 and 56 Available settings ...

Страница 17: ...ature door window opened 2048 ID 51 low temperature door window closed Default setting 0 none Parameter size 2 bytes 71 Alarm broadcast Settings for broadcasting ON OFF commands sensor alarm and tam per alarm Value other than 0 means alarms are sent in Broadcast Mode to all devices only within the range of the device They are not repeated by the mesh network Available settings 0 broadcasts inactiv...

Страница 18: ...up Lifeline Available settings 0 none of the groups sent as secure 1 2nd group Control sent as secure 2 3rd group Alarm sent as secure 4 4th group Sensor ZW3 sent as secure 8 5th group Tamper ZW3 sent as secure Default setting 15 all Parameter size 1 byte NOTE Operating in Z Wave network security mode automatical ly disables sending alarms in broadcast mode i NOTE Values of parameter 72 may be com...

Страница 19: ... building structure 0 40 C single DS18B20 76 x 17 x 19 mm 10 Specifications TMP button used for including excluding the device and tamper detection TP TEMP_POWER power supply terminal of temperature sensor TD TEMP_DATA signal terminal of temperature sensor GND GROUND ground terminal IN potential free input TP VDQ TD DQ GND IN TMP TOP VIEW MAGNETIC SENSOR NOTE Radio frequency of individual device m...

Страница 20: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry Canada IC Compliance Notice This device complies with Industry Canada license exempt RSSs Ope ration is subject to the following two conditions 1 this device may not cause ...

Страница 21: ...ric machinery Article 14 The application of low power frequency electric machineries shall not affect the navigation safety nor interfere a legal communication if an interference is found the service will be suspended until improvement is made and the interference no longer exists 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用 者均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現 有干擾現象時 應立即停用 並改善至無干擾...

Отзывы: