FIBARO FGFS-101 Скачать руководство пользователя страница 1

CONTENTS

#1: Description and features 

4

#2: Basic activation 

5

#3: Adding/removing the device 

6

#4: Diagrams and connection 

7

#5: Powering modes 

9

#6: Operating the device 

10

#7: Association 

12

#8: Z-Wave range test 

13

#9: Advanced parameters 

14

#10: Specifications 

19

#11: Regulations 

20

FIBARO FLOOD SENSOR

FGFS-101

O P E R A T I N G

M A N U A L

EN

v2.0

Содержание FGFS-101

Страница 1: ...g removing the device 6 4 Diagrams and connection 7 5 Powering modes 9 6 Operating the device 10 7 Association 12 8 Z Wave range test 13 9 Advanced parameters 14 10 Specifications 19 11 Regulations 20 FIBARO FLOOD SENSOR FGFS 101 O P E R A T I N G M A N U A L EN v2 0 ...

Страница 2: ......

Страница 3: ...ices are not only receivers but can also repeat the signal increasing the Z Wave network s range It gives advantage over traditional wireless systems that require direct link between transmitter and receiver as a result the construction of the building could affect network s range negatively Every Z Wave network has its unique identification number home ID Multiple independent networks can exist i...

Страница 4: ...es or additionally to any alarm system controller through opening a NC contact using the external power supply The device has built in temperature sensor that allows to monitor ambient temperature FIBARO Flood Sensor is designed to be placed on the floor or mounted on a wall in this case Flood Sensor probes should be extended using addition wire The device has a built in visual LED indicator and a...

Страница 5: ...ce should evenly touch the surface Beep NOTE After completing installation it is rec ommended to test sensor s operation by placing the entire sensor or its probes extension wire onto water surface i NOTE When changing the Sensor s location it s recommended to wake up the device and re configure the Z Wave network by triple click ing the TMP button or removing and insert ing the battery i NOTE Whe...

Страница 6: ...our Z Wave controller 3 Set the main controller in security non security add mode see the controller s manual 4 Quickly three times press the TMP button 5 Wait for the adding process to end 6 Successful adding will be confirmed by the Z Wave controller s message Removing Exclusion Z Wave device learning mode allowing to remove the device from existing Z Wave network To remove the device from the Z...

Страница 7: ...s TMP tamper button used to add remove the device ALARM NC TAMP NC SENS 1 SENS 2 12 GND TMP 4 Diagrams and connection 1 2 3 12 24 VDC ADAPTER ALARM NC TAMP NC SENS 1 SENS 2 12 GND TMP Connection to a constant power source NOTE The TMP button has two functions 1 Adding Removing the device to from the Z Wave network 2 Tamper contact for 4th Association Group When a sen sor is added to the Z Wave net...

Страница 8: ...ction only Do not connect external voltage NOTE ALARM NC and TAMP NC connectors may be used as end of line protective loop s ter minals i NOTE The Sensor detects electrical conductivity between electrodes 1 and 3 1 and 2 and electrodes connect ed to contacts SENS1 and SENS2 i If you want the device to be mounted on a wall or in a distance from flooding source sensor should be extended using an ext...

Страница 9: ...tage power source 12 24 VDC to 12 and GND terminals in accordance with Diagrams and connection on page 7 3 Add the sensor to the Z Wave network The Flood Sensor may operate without a battery if 12 24V power sup ply is connected Installing a battery is recommended though as it will serve as an emergency power source When constant power fails sensor will automatically shift to backup power mode All ...

Страница 10: ...er no 63 set to 1 visual indicator will periodically show temperature readouts depend ing on parameter 50 51 61 and 62 settings 3 In constant powering mode the current temperature readouts will be continuously signalled with a colour depending on param eter 50 51 61 and 62 settings 4 Currently selected menu position is signalled with an illumination colour TMP button NOTE By default flood sen sor ...

Страница 11: ...n 6 After few seconds the device will restart with factory settings which is signalled with the red visual indicator colour and an acoustic signal Waking up the Flood Sensor When in battery mode the Flood Sensor needs to be woken up to receive information about the new configuration from the controller like parameters and associations To wake up the sensor manually click the TMP button located ins...

Страница 12: ...ociation Group Tamper Alarm is assigned to the TMP button and tilt sensor devices in this group will receive a notification when the sensor is moved or the cover is taken off which normally holds the button Useful for devices that can trigger alarms Func tionality can be altered by parameter 74 To add an association using the FIBARO Home Center controller 1 Go to device options by clicking the ico...

Страница 13: ... does communi cate at the maximum distance of the Z Wave network If connection proves successful it will be confirmed with a yellow glow It s not rec ommended to use the device at the range limit Visual indicator glowing red the Flood Sensor is not able to con nect to the main controller directly or through another Z Wave net work device repeater CAUTION To make Z Wave range test possible the de v...

Страница 14: ...vailable in the FIBARO interface as simple options that may be chosen by selecting the appropriate box In order to configure the Flood Sensor using the FIBARO Home Center controller 1 Go to the device options by clicking the icon 2 Select the Advanced tab Wake up interval battery mode Available settings 0 or 60 86400 in seconds 1min 24h Default setting 21 600 every 6 hours The Flood Sensor will wa...

Страница 15: ...es WILL NOT be informed when the flooding has ceased It is still possible to cancel alarms in 3rd association group by choosing second green menu position see Menu visual indications on page 10 Available settings 0 alarm flooding cancellation inactive 1 alarm flooding cancellation active Default setting 1 Parameter size 1 byte 10 Temperature measurement interval Time interval in seconds between co...

Страница 16: ...ngs By default the visual indicator blinks red Available settings 10000 to 10000 each 0 01 C Default setting 3500 35 C Parameter size 2 bytes 61 Low temperature alarm indicator colour Parameter stores RGB colour value see the note below for details Available settings 0 16777215 Default setting 255 Parameter size 4 bytes 62 High temperature alarm indicator colour Parameter stores RGB colour value s...

Страница 17: ...C Parameter size 2 bytes 74 Alarm frame sent to 1st and 4th Association Group activation MOVEMENT_TAMPER BUTTON_TAMPER The device is able to report tamper alarms resulting from sensor s tilt movement or TMP button state change e g taking off the top cover Available settings 0 tamper alarms inactive 1 button tamper alarm active 2 movement tamper alarm active 3 button and movement tampers alarm acti...

Страница 18: ...D OFF does not change its state in the main controller does not send alarm notifications nor turn on off commands to 2nd 3rd association groups with flood state changes Always visible in the main controller as turned off Default setting 0 Parameter size 1 byte 78 Associations in Z Wave network security mode This parameter defines how commands are sent in specified associa tion groups as secure or ...

Страница 19: ...9 5 EC Z Wave 500 series chip 868 4 or 869 8 MHz EU 908 4 908 42 or 916 0 MHz US 921 4 or 919 8 MHz ANZ 869 0 MHz RU up to 50m outdoors up to 40m indoors depending on terrain and building structure 0 40 C 20 100 C 0 5 C within 0 40 C range 72 x 28 mm 10 Specifications NOTE Radio frequency of individual device must be same as your Z Wave controller Check information on the box or consult your deale...

Страница 20: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry Canada IC Compliance Notice This device complies with Industry Canada license exempt RSSs Ope ration is subject to the following two conditions 1 this device may not cause ...

Страница 21: ...hall not affect the navigation safety nor interfere a legal communication if an interference is found the service will be suspended until improvement is made and the interference no longer exists 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用 者均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現 有干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射頻電機須忍受合法通信或工業 科學及醫療用電波輻射性 電機設備之干擾 Information accor...

Отзывы: