Fetco E1241IN-1B123-PM000 Скачать руководство пользователя страница 2

Go to fetco.com for the latest versions of all information         

Page 2

      

User Guide & Operator instructions

   

P212

e0

November 2021

 

Specifications and Requirements 

Water Requirements:

 

Electrical: 

See electrical configuration chart. 120 

Volt; 208-240 Volt; 230 Volt and user configurable 

CBS-1241 &1242: 20-75 psig, (138-517kPa) 1½gpm/(5.7lpm)

 

Water inlet fitting

 is a 3/8 inch male flare. 

Brewer supplied with inlet valve adaptor for BSP to SAE 

Tank Temperature, as set by factory:  

200°F (93°C) inside water tank (at sea level)

 

Brew Volume: Full Batch

 1 gallon; (second batch  ¾ gallon) 

User adjustable from 0.26 gallon to 1-1/4 gallons per brew 

Water supply: (Optimal) 100-150TDS

  

All beverage equipment must use filtered water. 

Calibrated for 1.0 gal brew/3.75 L & ¾ gallon per brew  Brew Basket 13” X 5”  Coffee Filter 13” X 5 or FETCO# F002 

Total Brew Cycle—

Factory default setting: First batch: 5:30 minutes=[4 minute brew time + 1.30 minute drip delay] 

    Second batch: 5:00 minutes=[3:30 minute brew time + 1:30 minute drip delay] 

Brew-Process parameters are user controllable for:  

Brew Volume, Brew Time, Prewet Percent, Prewet Delay, Bypass, and Drip Delay

 

Weights and Capacities 
Model 

Height 

Width 

Depth 

Water tank 

capacity 

Empty 

Weight 

Filled 

Weight 

Shipping 

Weight 

Shipping Dimensions 

CBS-1241 

Brewer 

34 ½ in 

880 mm 

11 ¾ in 

300 mm 

20 3/8 in 

520 mm 

4.5 gallon 

17 L 

29 lbs 

13.2 kg 

55 lbs 

25.0 kg 

41 lbs 

18.6 kg 

35” x 17” x 22” 

88.9 x 43.2 x 55.9 cm 

CBS-1242 

Brewer 

34 ½ in 

880 mm 

19 ¾ in 

500 mm 

20 3/8 in 

520 mm 

8.5 gallon 

32 L 

47 lbs 

21.3 kg 

92 lbs 

41.7 kg 

58 lbs 

26.. kg 

35” x 23” x 25” 

88.9 x 58.4 x 63.5 cm 

Calibrated for 1.0 gal brew/3.75 L 

Brew Basket 13” X 5” 

Coffee Filter 13” X 5 or FETCO# F002 

Rough-In Drawings  

1201.00060.00 (CBS-1241)  1201.00061.00 (CBS-2142) 

      CBS-1242 Front 

     CBS-1241 Front 

Side (both) 

     Back (both) 

  EXAMPLE: SKU E1241US-1A115-PM001  

SKU NUMBER IDENTIFICATION KEY

Product Line 

Level 

Family 

Region ID 

Phase  Voltage Range  # Heaters 

Individual 

Heater Wattage 

Brew 

Basket 

Hot Water 

Faucet 

Bypass  Brew Basket 

Locks 

Power Cord 

E=extractor 

US =United 

States 

A = 100-120 

1.5 

P=plastic  M=manual  1=Yes 

1=Yes 

0=Terminal Block 

12=PLUS 

Series 

41= 

single side 

IN = 

International 

B = 200-240 

1.7 

M=metal  A=automatic  0=no 

0=no 

1= NEMA 5-15P 

42= 

dual side 

CE = CE 

C = 380-415 

2.3 

N=None 

2=NEMA 5-20P 

 

NM = NOM  U = 1 or 3  D = 440-480 

3.0 

3=NEMA 6-15P 

 

 

 

4.0 

4=NEMA 6-30P 

X=120 or 240 

Dual Voltage 

5.0 

5=CEE 7/7 Schuko 

6=UK1-13P 

7= AUSTRALIAN 

Содержание E1241IN-1B123-PM000

Страница 1: ...ractor Plus Brewing System FETCO PLUS Commercial Beverage Equipment CBS 1242 CBS 1241 1 gallon Extractor Plus Brewers shown with 1 gallon L4D dispenser sold separately CONTACT INFORMATION FETCO FOOD E...

Страница 2: ...elay Weights and Capacities Model Height Width Depth Water tank capacity Empty Weight Filled Weight Shipping Weight Shipping Dimensions CBS 1241 Brewer 34 in 880 mm 11 in 300 mm 20 3 8 in 520 mm 4 5 g...

Страница 3: ...i on Phase Amp Dr aw Brew Volum e per hour E1241C E 1B130 PM000 230 1 X 3 0 kW L N PE 2 8 EU1 16P 1 12 5 7 7 gal 29 1 L CBS 1241PLUS Single 1 Gallon 3 0 4 0 Liter Coffee Brewers Field configurable Int...

Страница 4: ...rew basket 5 Select a batch hold the corresponding BREW button in for 1 second to start 6 STOP button will illuminate Countdown time will display Selected BREW button will flash to indicate brew is in...

Страница 5: ...3 Service Phone G15 Rt Brews A90 Copy Batch B13 Filter Life F14 Override Lt BBS See Page 12 A91 Copy Batch From F15 Override Rt BBS A92 PASTE To F16 Override Lt BBL F17 Override Rt BBL Left and Right...

Страница 6: ...brew time is 5 30 minutes A2 30 Prewet Perc 0 0 00 25 0 1 Percentage of total brew volume A2 40 Prewet Delay Brew pause after prewet completes 0 1 00 Min 0 10 5 00 1 00 min The time between prewettin...

Страница 7: ...mperature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 205 212 0 96 100 0 500 152 205 211 0 96 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 2...

Страница 8: ...Activates valve Default is 10 sec Toggle OFF or ON Runs valve to verify flow NOTE Have container under brew basket D4 Rt right Brew Valve Test Press to test Activates valve Default is 10 sec Toggle OF...

Страница 9: ...te 1 85 liter minute 64 ounces minute 0 42 0 58 Gallons 1 55 2 20 Liters 53 74 fl ounces 0 01G 0 05L 1 oz Adjusts flow rate E6 LT Bypass valve flow rate 0 37 gallon minute 1 60 liters minute 47 ounces...

Страница 10: ...NO Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F10 Restore Defaults NO NO YES Reset to factory When selecting F10 RESTORE...

Страница 11: ...k did not refill within expected time Water supply flow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 200 Heating flatline Tank is b...

Страница 12: ...nt Totalized cycles of valve operation CBS 1241 CBS 1242 G29 A Rt Brew Cycles R G30 A Rt Brew Volume LT Right brew valve flow through volume Gallons Liters Totalized volume through right valve CBS 124...

Страница 13: ...toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT Note Only the left side buttons of a two sided brewer are used for programming NOTE User Settings will be er...

Страница 14: ...such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petroleum based polish a...

Страница 15: ...ible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in a position to facilitate filter replacement 6...

Страница 16: ...nit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or aut...

Страница 17: ...BB HANDLE 1023 00191 00 GREEN PLUG BB HANDLE 1023 00192 00 ORANGE PLUG BB HANDLE 1023 00180 00 BLUE PLUG BB HANDLE Stainless Steel Brew Basket Ref Qty Part Number Description B003218B1 Complete Stain...

Страница 18: ...sions of all information Page 18 User Guide Operator instructions P212e0November 2021 Parts Diagram CBS 1241 FETCO CBS 1241 Drawing Number 1101 00580 00 6 Part Number1102 00471 00 ELECTRICAL COMPONENT...

Страница 19: ...1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 31 1 1046 00003 00 LABEL CSD WARNING 1 5 X 5 0 32 1 1041 00033 00 BLACK EXTRACTOR PLUS LABEL LASER ENGRAVED 33 1 1402 00097 10 WI...

Страница 20: ...ions of all information Page 20 User Guide Operator instructions P212e0November 2021 Parts Diagrams CBS 1242 FETCO CBS 1242 Drawing Number 1101 00579 00 6 Part Number1102 00471 00 ELECTRICAL COMPONENT...

Страница 21: ...2232 42 28 1 1001 00409 00 COVER UPPER BASE CBS 2232 42 29 12 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X LG 30 1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 31 2 1046 00...

Страница 22: ...ATED 9 1 1107 00030 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 1 1107 00031 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 1 1107 00029 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 9 1 1107 00037 00 HEATER...

Страница 23: ...0 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00030 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 2 1107 00031 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 2 1107 00029 00 HEATER ASSEMBLY...

Страница 24: ...8 12 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00037 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 9 2 1107 00005 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 9 2 1107 00010 00 HEATER ASSEM...

Страница 25: ...1102 00113 00 SWITCH REED ASSEMBLY 5 1 1102 00479 00 ASSEMBLY CASCADE SPRAY DOME NEXT GEN ORANGE 6 2 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL interchangeable with 1057 00078 00 6 2 1057 00078...

Страница 26: ...6 User Guide Operator instructions P212e0November 2021 Wiring Diagrams SSR SSR SKU E1231 US 1X117 Domestic Dual Voltage Brewer is supplied by factory as 120VAC For 208 240 volt application conn ect L1...

Страница 27: ...ons of all information Page 27 User Guide Operator instructions P212e0November 2021 S S R Wiring diagram 1401 00190 10 CBS 1241PLUS SKU E1241US 1A115 PM001 E1241US 1A123 PM002 E1241IN 1B123 PM000 E124...

Страница 28: ...ions of all information Page 28 User Guide Operator instructions P212e0November 2021 SSR Wiring diagram 1401 00196 10 CBS 1242 PLUS SKU E1242US 1B223 PM000 E1242US 1B230 PM000 E1242IN 1B223 PM000 E124...

Отзывы: