Go to fetco.com for the latest versions of all information         Page 20               

  

P183   March 2019

 

Troubleshooting 

Brewing Problem 

Possible Cause 

Solution 

Brew handle

 will not stay down 

Power switch off. 

-Turn switch on. 

 

No power to the brewer 

(Brewer lights are not illuminated) 

-Make sure the brewer is plugged in. 

-Check the wall circuit breaker / reset 

-Turn the brewer power switch off then back on (it has an 

internal breaker) 

 

Bad timer or dispense latch 

assembly. 

(Brew light 

does not 

come

 

on and 

handle won’t stay down) 

-Check for voltage reaching the timer from the dispense 

latch assembly if yes replace timer. If no, replace latch 

assy. 

 

Bad dispense latch assy. 

(Brew light 

does 

come on

 

and 

handle won’t stay down) 

-Replace the dispense latch assembly 

 

Bad dispense latch assembly 

(brewer buzzes when in brew cycle) 

-Replace the dispense latch assembly 

Brew handle

 stays down but no water is 

dispensed 

No water reaching the brewer 

-Make sure the shut off valve is open. 

-Check water line for kinks; replace line if necessary 

-Check to see if filter is clogged by changing it. 

Short brew levels  

EVERY BREW

 

 

Flow discs in spray heads in upside 

down 

-Reassemble spray heads - bumps on spray cutter face 

 

with flange on flow disc facing 

 

 

Water filter clogged 

(See details in next section) 

 

Spray head clogged 

-Clean and or replace the sprayhead 

(

One or

 

Both sides

 are 

Timer/s are set too low 

-Advance timers to proper level. 

affected and levels are

 consistent

Incoming Voltage is too low for 

timers to function at proper time 

sequences 

-Reset wall circuit breaker as one side may drop out & not 

flag the breaker. 

-Call an electrician to find loose connections in the building 

Short brew levels  

SOME BREWS

  

 

Water filter clogged. 

(problem is worse during 

simultaneous brews) 

-Replace water filter 

 

Weak dispense latch assembly 

(usually buzzes during cycle) 

-Replace dispense latch assembly. 

(

One or

 

Both sides

 are affected and 

levels are 

erratic

Water pressure or flow rate is too 

low or fluctuates too much to 

support a full brew. 

(problem is worse in simultaneous 

brews) 

-Make sure brewer has a dedicated water line 

-Ensure that the shut off valve is open all the way (Never 

use needle saddle valves) 

-Increase the diameter of the water line to the brewer and 

or find stable source. 

Brew Time required to fill LUXUS are 

not the same for both sides

 

Brewer is not level 

-With an accurate level, level the brewer front to back and 

left to right by adjusting the feet. 

High brew levels    

EVERY BREW 

(overfills but does stop) 

Timer/s are set too high 

-Adjust timers down to appropriate level 

                               SOME BREWS 

Thermal server not empty 

-Empty the server and try again 

Brew basket or filter overflows 

 

-Call FETCO Service Dept. to discuss. 

    (800) 338-2699 

Weak Coffee

 

Spray head missing 

-Attach spray head assembly. 

 

Improper dose 

-Measure and confirm correct dose 

 

Filter papers 

-Make sure only one paper is used 

 

Cracked dispense tube 

-See  “spray head drips MAJOR”, below 

 

Low brew temperature 

(Temperature inside the hot water 

tank is set to 205

°

 F, the metal 

delivery system drops the temp.) 

-Adjust thermostat so the water stream measured at the 

bottom of the brew basket, 1/3 of the way through the brew 

cycle, equals 190 d or - 5 degrees 

Grounds not saturated

 

Spray head missing 

-Replace spray head 

 

Half batch used incorrectly 

-Use smaller “half batch” brew basket 

 

 

-Discourage half batch use  

 

 

-Investigate the need for a smaller brewer 

 

Water Softener in use 

-Move brewer water feed to a non-softened source. 

 

Degassing - extremely fresh coffee 

-Call FETCO Service Dept. to discuss. 

    (800) 338-2699 

No bypass

     EVERY BREW 

 

Bypass valve closed 

-Open bypass valve 

                       SOME BREWS

 

Flow disc wrong size or missing 

-Correct or replace flow disc 

Spray head / brew basket drips either 

side or both 

 

MINOR 

Condensation around the 

sprayhead area 

-Wipe sprayhead area after brewing; place an empty 

container under brew cone when not in use. 

 

Condensation from water tank 

dripping through dispense tube 

-Insert an empty brew basket and server under brew heads 

when not in use 

  

 

Содержание CBS-5000H Series

Страница 1: ...ingle1 Gal CBS 51H15 Right Dual 2 Gal CBS 52H20 Contact Information FETCO Food Equipment Technologies Company 600 Rose Road Lake Zurich IL 60047 1560 USA 2008 2019 Food Equipment Technologies Company...

Страница 2: ...lf batch brewing capability Fully automatic with electronic temperature control Iced tea brewing capability Two level tank drain system Total serviceability from the front Can be added at any time Spe...

Страница 3: ...ph 3 ground 6 1 25 8 9 9 22 0 120 208 1 ph 3 ground 6 1 29 6 9 9 22 0 C52026 2 X 4000 watt 120 220 1 ph 3 ground 6 8 31 3 11 5 22 0 120 240 1 ph 3 ground 8 1 34 1 13 2 22 0 120 208 3 ph 4 ground 6 9...

Страница 4: ...Go to fetco com for the latest versions of all information Page 4 P183 March 2019 Dimensions Utility Connections CBS 51H15 CBS 52H15 CBS 52H20...

Страница 5: ...ing Verify that the brewer will fit in the space intended for it and that the counter or table will support the total weight of the brewer and dispensers when filled 2 The brewer s legs are shipped in...

Страница 6: ...tubes 2 Turn on the incoming power 3 Turn on the brewer s main power switch 4 Within 6 seconds the hot water tank will begin filling until the probe at the top of the tank senses the water 5 The contr...

Страница 7: ...ion This was done to help draw attention to the basket so the operator will notice any residual hot water or coffee Place a paper filter in each basket to be used Pour into the paper filter the approp...

Страница 8: ...never the power switch is turned on voltage will not be supplied to the thermostat until the tank fills and water touches the water level probe During operation when water is dispensed and the water l...

Страница 9: ...cutter controls the rate of flow over the coffee The standard hole in the flow disc is 240 except for the CBS 51H10 which is 219 Other flow discs are available for special situations like high levels...

Страница 10: ...ISPENSE TUBE SHAFT DISPENSE TUBE To remove the dispense tube 1 Unscrew seal locknut and release the drive screw from dispense tube shaft 2 Turn the dispense tube slightly back and forth while pushing...

Страница 11: ...will flash indicating that the display is showing the set point not the actual temperature The dots below the numbers indicate the temp range 0 dots less than 100 F 1 dot between 100 and 200 F 2 dots...

Страница 12: ...is energized Bypass Adjustment The purpose of the bypass valve is to allow a portion of the brewing water to flow between the brew basket and the wire insert directly into the server without coming in...

Страница 13: ...NUT SEAL 7 16 DIA KEEPER 17 2 1031 00033 00 LOCKNUT 3 8 18 NPT THREAD 18 1 1031 00022 00 FITTING ELBOW 3 8 TUBE OD X 3 8 NPT 19 1 1023 00003 00 LOCKNUT MODIFIED THREAD 1 4 18 NPT 20 1 1083 00006 00 WA...

Страница 14: ...Go to fetco com for the latest versions of all information Page 14 P183 March 2019 Figure 2 CBS 51H15 Main Assembly Drawing No 1101 00268 00 CBS 51 H...

Страница 15: ...AMP READY INDICATOR GREEN 220VAC EXPORT ONLY 26 1 1045 00022 00 OVERLAY CONTROL PANEL CBS 51H 27 1 1058 00011 00 LAMP BREW INDICATOR CLEAR 110VAC 27 1 58004 LAMP BREW INDICATOR CLEAR 220VAC EXPORT ONL...

Страница 16: ...Go to fetco com for the latest versions of all information Page 16 P183 March 2019 Figure 3 CBS 52H15 CBS 52H20 Main Assembly Drawing No 1101 00262 00 CBS 52H...

Страница 17: ...SPRAY CUTTER 8 1 075 CENTER 29 2 1012 00004 00 LOCKNUT SPRAY CUTTER 30 2 25001 TUBESILICONE 1 2 x 1 4 ID x 2 7 8 LG 31 2 1112 00041 00 DISPENSE TUBE WELDMENT CBS 50 S 32 1 102010 BREW HANDLE START STO...

Страница 18: ...00024 00 FITTING COMP MALE CONN 3 8 TUBE X 3 8 17 1 1031 00020 00 LOCKNUT 1 8 STRAIGHT PIPE THREAD 18 1 1083 00014 00 WASHER 812 OD X 0 412 ID FLAT 19 1 1031 00032 00 FITTING BARB ELBOW 90 1 4 HOSE ID...

Страница 19: ...BREW BASKET HANDLE BLACK includes magnet 3 1 1082 00040 00 HANDLE SCREW 4 1 1009 00005 00 WIRE INSERT 16 X 6 5 1 1046 00025 00 WARNING LABEL NOT SHOWN F001 PAPER FILTERS 15 X 5 5 500 PER CASE NOT SHO...

Страница 20: ...evels are erratic Water pressure or flow rate is too low or fluctuates too much to support a full brew problem is worse in simultaneous brews Make sure brewer has a dedicated water line Ensure that th...

Страница 21: ...isconnect the outlet side to see if it leaks water to the tank Coffee tastes too strong Incorrect dosage Measure and confirm the correct amount of coffee required Short brew levels See Short brew leve...

Страница 22: ...End of section notes N...