6
Technical data
ECU 45
Supply voltage (input)
230 - 240 V ~
Line frequency
50/60 Hz
Charging voltage (output)
7.2 14.4 V (DC)
Charging current
Quick charge
max. 3 A
Compensation charge pulsating app.
0.06 A
Charging time for
NiCd 1.4 Ah
app. 38 min
NiCd 1.7 Ah
app. 42 min
NiCd 2.0 Ah
app. 46 min
NiMH 3.0 Ah
app. 70 min
Weight
0.5 kg
The illustrations mentioned can be found on a fold-
out page at the beginning of the operating
instructions.
1
Directions for use
The charger ECU 45 has been designed to charge
the battery packs specified under Chapter 2.
The user will be liable for damage due to improper
use.
For your own safety
Repairs may only be carried out by qualified
experts.
Warning:
ECU 45 charging device: Even
after disconnection from the mains, there is still a
high capacitor voltage on the power output
component on the inside of the device.
Protect equipment against moisture.
Do not use the charger if the connecting cable is
damaged, unplug immediately from the main.
Protect the cable against heat, oil and sharp
edges.
Never carry the tool by its cable and never use to
the cable to pull the plug out of the wall socket.
Do not use defect and damaged battery packs.
Only use original Festool battery packs. Do not
use spent and recycled battery packs. The user
shall be liable for damages if Festool original
battery packs are not used.
Do not place spent battery packs into fire or into
domestic waste.
Attention:
Festool offers an
ecological friendly waste disposal for used battery
packs (refer to RECYCLING OF BATTERY
PACKS).
Do not open battery packs.
Do not store battery packs with metal objects
(danger of short circuit).
No metal objects (metal chips) should enter the
charger at the contact points as well as through
the cooling slits into the equipment (danger of
short circuit).
Keep out of reach of children.
Check the tool for damages before use. Have
damaged parts repaired or replaced by the
customer service department.
2
Charge battery pack
All NiCd and NiMH battery packs between 7.2 V
and 14.4 V voltage can be charged with the
ECU 45 charger.
The battery type used (NiCd or NiMH) is detected
automatically. Charging is controlled by a
microprocessor.
Warning:
If a warm NiMH battery pack (>37°C) is
inserted, charging will only be carried out at a lower
charge current.
In this case the charging time for a battery pack
with 3.0 Ah is around 100 min..
By the influence of powerful electromagnetic
perturbations while charging it can be switched over
to conservation charge.
Thereby the charger can not take in a dangerous
or unsafe status
The LED (1.10) shows the charge status of the
charger.
LED yellow - steady
= Charger is ready for use.
LED green - flashing
= Battery pack being charged.
LED green - steady
= Battery pack fully charged, conservation charge
on.
LED red - flashing
= General malfunction, e. g. full contact not being
made, short-circuit, battery pack faulty.
LED red - steady
= Temperature of battery pack is outside
permissible limit (5° - 45°C).
Charging
Connect charger to mains.
Warning:
The line voltage and frequency must
correspond with the data on the ratings plate!
Insert battery pack into charging chamber:
Insert battery pack with the fin (1.4 or 1.5) in the
lower groove (1.1) of the charging chamber.
Push battery pack into charging chamber until it
catches with the lock (1.9 or 1.7) in the groove (1.2
or 1.3). The battery pack is now charged.
Press the button (1.8 or 1.6) to unlock it and remove
it from the charger.
Seen at Ideal Tools.