10
Festo — YJKP-ST/MT — 2021-11f
Installation
Additional steps
1. Insert the memory card (microSD card) into the CECC-X-M1-YS.
2. Mount controller CECC-X-M1-YS.
Follow controller user documentation CECC-X-M1-YS
3. Mount controller CMMP-AS.
Note motor controller user documentation CMMP-AS-...-M0
Up-to-date information on the accessories
7
Installation
7.1
Safety
WARNING
Risk of injury due to lowering piston rod.
• Before working on the product: Secure the piston rod to prevent it from lowering.
WARNING
Risk of injury due to unexpected movement of the product.
Electrical energy can cause unexpected movement of the product.
• Before working on the product: Switch off the power supply, ensure that it is off and secure it
against being switched on again.
NOTICE
Material damage as a result of using the wrong connections.
In accordance with intended use, all unnamed connections must not be used.
Details on handling the individual components of the kit are described in separate documents
7.2
Electrical installation - cables
Connecting cable NEBS-M12G5-ES-...-LE5
The connecting cable connects the sensor on the electric cylinder with the analogue input [X19] on the
controller CECC-X-M1-YS.
The accompanying plug must be mounted on the open cable ends.
Sensor SKDA
Connecting cable NEBS-M12G5-ES-...-LE5
Controller
CECC-X-M1-YS
Pin
Wire colour
1)
Signal
Connection [X19]
1
BN
24 V DC
Power supply for sensor
X19.0.1
2
WH
not used