Power supply CECC-D-BA [X1]
•
Intrinsic current consumption:
£
100 mA
•
Use an external overload protection for the power supply of the device.
Terminal
Connection
Use
X1.1
24
24 V DC
X1.2
0
0 V DC
X1.3
Functional earth
X1.4
Not assigned
–
Tab. 8 Power supply connection CECC-D-BA
1. Supply the device with power.
2. Place the open cable ends in the plug provided in accordance with the table.
3. Insert the plug into the connection [X1] of the balancer controller CECC-D-BA.
Power supply of the digital I/Os [X5]
Resultant current for all supplied ports:
£
2 A
Terminal
Connection
Use
X5.1
24
24 V DC
X5.2
0
0 V DC
Tab. 9 Connection, power supply for digital I/Os
1. Supply the device with power.
2. Place the open cable ends in the plug provided in accordance with the table.
3. Insert the plug into the connection [X5] of the controller.
Connection, reference sensor
Connect the proximity sensor SMT-8M-A-PS-24V-...-OE that serves as a reference sensor as follows.
SMT-8M-A-PS-24V-...-OE
CECC-D-BA
Wire colour
1)
Function
Connection
BN
24 V DC supply
24 V load
BK
Switching output
Digital input X2.3
BU
GND
24 V GND
1) Colour code in accordance with IEC 60575:1983-01
Tab. 10 Connection, reference sensor
Installation
18
Festo — YHBP-2 — 2018-11