VZWM
Festo VZWM 0612NH English
23
7
Co
mm
i
ss
ionin
g
Ple
as
e note
The VZWM diaphragm valve is operated via the integrated 2/2−way pilot
control.
S
Use a suitable coil foractuating the solenoid armature
(
è
chapter 10 Accessories).
S
Take into account the fact that when the pressure is switched on suddenly, the
valve will open briefly. The output side must therefore be connected.
Function test using incompressible media
S
Fill the tubing system with the medium used.
Function test using all media
S
Apply the desired input pressure to the diaphragm valve (e. g.6bar).
The valve will then be closed.
Note the maximum permitted rated pressure (
è
chapter 12 Technical
specifications).
8
O
per
a
tion
S
Make sure that the minimum difference in pressure for switching between the
input and output of the diaphragm valve is available (
è
chapter 12 Technical
specifications).
Using compressed air with a medium temperature < 1 °C:
S
Avoid the dew point being reached.
If the dew point is reached, the diaphragm will ice up and become stiff. The set
switching values of the valve will then be modified.
S
If necessary, use dried compressed air.
Содержание VZWM
Страница 16: ...VZWM Festo VZWM 0612NH Deutsch 16...
Страница 30: ...VZWM Festo VZWM 0612NH English 30...
Страница 44: ...VZWM Festo VZWM 0612NH Espa ol 44...
Страница 58: ...VZWM Festo VZWM 0612NH Fran ais 58...
Страница 72: ...VZWM Festo VZWM 0612NH Italiano 72...
Страница 86: ...VZWM Festo VZWM 0612NH Svenska 86...
Страница 87: ...VZWM Festo VZWM 0612NH 87...