104
Festo — VTSA-F-CB — 2021-06a
Technical data
Throttle plates width 52 mm
1
2
Fig. 64: Flow rate qn as a function of the revolutions n of the adjusting screw
1
Flow rate from (2) to (3)
2
Flow rate from (4) to (5)
12.4
Technical data, electrical
Electrical
Width
18 mm
26 mm
42 mm
52 mm
Load voltage supply for valves (DC)
U
VAL
[V]
24 ± 10%
25 … 26.4 (for configurations with an overall
length of
³
1000 mm)
Diagnostic message undervoltage UOFF,
load voltage outside the functional
range
[V]
20.6 … 20.5
Operating voltage supply for electronics (DC)
U
EL/SEN
[V]
24 ± 25%
Current consumption per solenoid coil with LED at 24 V DC and 100% duty cycle from U
VAL
2x 3/2-way valves
[mA]
60
5/2 and 5/3-way valves
[mA]
72
all valves
–
Pick-up current
[mA]
–
165
–
Holding current (after 30 ms)
[mA]
–
35