background image

4.1

Structure

4.1.1

Product design

The product can consist of the following modules, depending on the configuration
ordered:

1

2

3

4

5

6

7

Fig. 1: Product design

1

CPX terminal electronics side

2

Controller Motion Terminal
CTMM-S1-C

3

Manifold rail

4

Input module CTMM-S1-A/D-…
(optional)

5

Pilot pressure regulator

6

Cover plate VABB-P11-27-T
(optional)

7

Valve slice VEVM-S1-27-…

The pressure regulator is set and sealed at the factory. This setting must not be
changed; doing so will invalidate the warranty.

4.1.2

Display components

This section describes the arrangement and function of the LEDs in the individual
modules. The meaning of the LED behaviour is described in 

è

 10 Diagnostics.

4.1.2.1 Controller

1

2

Fig. 2: LED displays on the controller

1

CPX-specific LEDs

2

Ethernet-specific LED

LED

Meaning

PL
(green)

Power Load

Monitor load voltage supply U

VAL

M
(yellow)

Modify

Parameterisation mode (via CPX bus node or WebConfig
interface)

SF
(red)

System Failure

Communication errors

PS
(green)

Power Functions

Monitor operating voltage supply U

EL/SEN

Tab. 4: CPX-specific LEDs

LED

Meaning

TP
(green)

Ethernet Link/
Traffic

Ethernet connection/data traffic

Tab. 5: Ethernet-specific LED

4.1.2.2 Valve

1

Fig. 3: LED display on valve

1

LED display on valve (red/blue)

LED

Meaning

(red)

Valve faults: VTEM manual 

è

 1.1 Applicable documents

(blue)

Operation/update

Tab. 6: LED display on valve

4.1.2.3 Input modules

1

2

Fig. 4: LED displays of the input

modules

1

LED display for input status (green,
digital input modules CTMM-S1-D-...
only)

2

LED display for module error (red)

LED

Meaning

(green)

Input status (digital input modules CTMM-S1-D-… only)

P

(red)

Short circuit/overload

Tab. 7: LED display for input modules

4.1.3

Control elements

The product has no mechanical control elements. Parameters and setpoint values
are only set using the WebConfig interface or the higher-order controller. The Web-
Config interface can be opened with a web browser if there is an existing Ethernet
connection to the controller of the Motion Terminal 

è

 8.1 Prior to commissioning.

4.1.4

Connecting elements

4.1.4.1 Connecting elements, electrical

1

Fig. 5: Functional earth connection

right

1

Functional earth connection

1

Fig. 6: Functional earth connection left

1

Functional earth connection (left-hand
end plate CPX terminal)

Содержание VTEM

Страница 1: ...drives due to leakage carry out the following steps before switching off the supply voltage Bring the system into the exhausted state App control app control Exhaust Disconnect the compressed air sup...

Страница 2: ...y UEL SEN Tab 4 CPX specific LEDs LED Meaning TP green Ethernet Link Traffic Ethernet connection data traffic Tab 5 Ethernet specific LED 4 1 2 2 Valve 1 Fig 3 LED display on valve 1 LED display on va...

Страница 3: ...the scope of the licensed Motion Apps For many Motion Apps the number of licences required is based on the desired number of valves on which the Motion App should run simultaneously Other Motion Apps...

Страница 4: ...ation of the electronics side of the CPX terminal and installation of the Motion Terminal VTEM WARNING Risk of injury due to electric shock For the electric power supply use PELV circuits that guarant...

Страница 5: ...ening torques for screws of the earthing conductor Correct seating of all plugs Tightening torque of the cable connectors Tab 10 Maintenance and repair work 9 2 Clean replace silencers NOTICE Malfunct...

Страница 6: ...re lights Logic 1 signal is pending off Logic 0 signal not pending Tab 19 LED display input status 11 Modification 11 1 Tightening Torques 1 2 3 4 5 6 Fig 9 Tightening Torques 1 0 4 Nm 10 2 1 5 Nm 20...

Страница 7: ...nsumption VTEM at 24 V DC typ via UEL SEN via UVAL Controller linkage mA 115 85 Per valve mA 28 24 Analogue input module plus intrinsic consumption of the sensors mA 12 0 Digital input module plus int...

Отзывы: