4.1
Structure
4.1.1
Product design
The product can consist of the following modules, depending on the configuration
ordered:
1
2
3
4
5
6
7
Fig. 1: Product design
1
CPX terminal electronics side
2
Controller Motion Terminal
CTMM-S1-C
3
Manifold rail
4
Input module CTMM-S1-A/D-…
(optional)
5
Pilot pressure regulator
6
Cover plate VABB-P11-27-T
(optional)
7
Valve slice VEVM-S1-27-…
The pressure regulator is set and sealed at the factory. This setting must not be
changed; doing so will invalidate the warranty.
4.1.2
Display components
This section describes the arrangement and function of the LEDs in the individual
modules. The meaning of the LED behaviour is described in
4.1.2.1 Controller
1
2
Fig. 2: LED displays on the controller
1
CPX-specific LEDs
2
Ethernet-specific LED
LED
Meaning
PL
(green)
Power Load
Monitor load voltage supply U
VAL
M
(yellow)
Modify
Parameterisation mode (via CPX bus node or WebConfig
interface)
SF
(red)
System Failure
Communication errors
PS
(green)
Power Functions
Monitor operating voltage supply U
EL/SEN
Tab. 4: CPX-specific LEDs
LED
Meaning
TP
(green)
Ethernet Link/
Traffic
Ethernet connection/data traffic
Tab. 5: Ethernet-specific LED
4.1.2.2 Valve
1
Fig. 3: LED display on valve
1
LED display on valve (red/blue)
LED
Meaning
(red)
Valve faults: VTEM manual
(blue)
Operation/update
Tab. 6: LED display on valve
4.1.2.3 Input modules
1
2
Fig. 4: LED displays of the input
modules
1
LED display for input status (green,
digital input modules CTMM-S1-D-...
only)
2
LED display for module error (red)
LED
Meaning
(green)
Input status (digital input modules CTMM-S1-D-… only)
P
(red)
Short circuit/overload
Tab. 7: LED display for input modules
4.1.3
Control elements
The product has no mechanical control elements. Parameters and setpoint values
are only set using the WebConfig interface or the higher-order controller. The Web-
Config interface can be opened with a web browser if there is an existing Ethernet
connection to the controller of the Motion Terminal
4.1.4
Connecting elements
4.1.4.1 Connecting elements, electrical
1
Fig. 5: Functional earth connection
right
1
Functional earth connection
1
Fig. 6: Functional earth connection left
1
Functional earth connection (left-hand
end plate CPX terminal)