1

Applicable documents

Document

Product

Contents

Manual

Proportional-pressure regulator VPPI-...-S1D

Assembly, Installation, Oper-
ating, Parameterisation

Test report

1)

Proportional-pressure regulator VPPI-...-T

Determined accuracies

1) Only if the test report was selected in the configurator when ordering the product. Available in the Support

Portal by entering the product key.

Tab. 1: Applicable documents

All available documents for the product 

è

  www.festo.com/sp.

2

Safety

2.1

Safety instructions

Only use the product in its original condition without unauthorised modifica-
tions.

Only use the product if it is in perfect technical condition.

Take into account the ambient conditions at the location of use.

Before working on the product, switch off the power supply and secure it
against being switched on again.

Before changing any settings in the menu of the proportional-pressure regu-
lator, read the manual of the product 

è

 1 Applicable documents.

2.2

Intended use

The proportional-pressure regulator is intended to regulate a pressure propor-
tional to a specified setpoint value.
The product may generate high frequency interference, which may require inter-
ference suppression measures in residential areas.
2.3

Training of qualified personnel

Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel have skills and
experience in dealing with electropneumatic (open-loop) control technology.

3

Additional information

Contact the regional Festo contact if you have technical problems

è

  www.festo.com.

Accessories and spare parts 

è

  www.festo.com/catalogue.

4

Product overview

4.1

Function

A built-in pressure sensor records the pressure at the working port and compares
this value with the setpoint value. In the event of deviations between the setpoint
value and actual value, the valve regulates until the outlet pressure has reached
the setpoint value.

VPPI -...- 3 -...
(normally closed)

VPPI -...- 4 -...
(normally open)

Tab. 2: Pneumatic Circuit Symbol

4.2

Product design

1

2

3

4

5

6

Fig. 1: Product design

1

Display

2

Operating buttons Display menu

3

Plug M12

4

Working air port (2)

5

Exhaust air port (3)

6

Compressed air port (1)

5

Transport and Storage

Store the product in a dry, UV- and corrosion-protected environment.

Ensure short storage times.

6

Assembly

6.1

Assembly

6.1.1

Linkage of valves

Up to 5 valves can be linked. The connecting kit VAME-P18-K-P5 is required for
linking 

è

  www.festo.com/catalogue.

The connecting kit consists of 2 square nuts, 2 socket head screws and an O-ring.
1. Remove the plug screw and sealing material from the duct (1).
2. Insert the O-ring into the duct (1) between 2 valves.

3. Connect the valves on the underside using socket head screws and square

nuts. Tightening torque: 1.2 ± 0.2 Nm

4. Connect valves at the rear using socket head screws and square nuts. Tight-

ening torque: 1.2 ± 0.2 Nm