If SP.O. is selected

1

2

3

4

Fig. 3: If SP.O. is selected

1 Hysteresis
2 Setpoint value

3 Actual value
4 SP.O. signal

8.4

Display symbols menu

Notes on the following table:
[x.xx] = pressure indicator for actual value or setpoint value
[ ... ] = input value, with flashing display

The main menu selection can be made in only one direction with the Selection
button 

V

.

Within a menu option the selection can generally be made with the 

v

 or 

V

button.

If a selection is not made in the main menu within 10 seconds or in a menu
option within 80 seconds, the display automatically jumps back to the initial
position, which is exception [Frc].

Menu = main menu selection
[x.xx] = value specification for setpoint value or actual value
Continue in the menu = press Edit button
If the display flashes (grey background) = you can make a selection with 

v

 

V

buttons
Change value [ ... ] = with 

v

 

V

 buttons

Save selection/value = press Edit button

No. Menu

Selection option 

v

 

V

1

[x.xx]

v

 (1 s) = [in]

V

 (1 s) = [out]

2

[Pr...]
[Pr...]

Pr1

Pr2

Pr3

3

[bAr]
[bAr]

bAr

PA

PSI

4

[OFS]
[ ... ]

5

[rnG]
[ ... ]

6

[Frc]

0.00 … 10.0 V (voltage variant)
4.00 … 20.0 mA (current variant)

[ ... ]

7

[An]
[An]

SP.O.

SP

SP.L

HY

[ ... ]

[ ... ]

[ ... ]

[ ... ]

[ ... ]

[ ... ]

HY

SP.H

[n.Lo/n.Hi]

[ ... ]

[ ... ]

[n.Lo/n.Hi]

[ ... ]

[ ... ]

[n.Lo/n.Hi]

HY

[n.Lo/n.Hi]

[ ... ]
[ ... ]
n.Lo/n.Hi
n.Lo/n.Hi

8

[Eco]
[OFF]
[OFF]

[1 … 999] sec.

9

[Pin]
[OFF]

No. Menu

Selection option 

v

 

V

[OFF]

[1 … 999]

back
to no. 1

Tab. 6: Display

9

Operation

NOTICE

When switching off the VPPE-..., make sure that the setpoint voltage or setpoint
current intensity is switched off first, then switch off the supply pressure and
finally the supply voltage.

The green status LED lights if the actual value is equal to the setpoint value of
within a range of ± 1% (FS) of the setpoint value.
Lock [Loc] - unlock [unL]
If a PIN code was entered with [Pin], [Loc] is shown in the display and the edit
mode is locked via the PIN code. If a flashing [0] appears, enter the correct pin.
After the correct PIN is entered, [unL] is displayed. If the input is incorrect, the
VPPE returns to the initial position.

10

Maintenance

Clean the housing of the VPPE-... with a soft cloth only. The permitted cleaning
medium is a mild detergent solution at maximum 50 °C.

10.1

Cleaning

For use with reduced particle emission:

Remove abraded particles and dirt from the product:

Prior to initial commissioning.

Regularly during operation.

11

Malfunctions

Malfunction

Possible cause

Remedy

VPPE-... does not react

No supply voltage, LED not on

Check the connection of the
24 V DC supply voltage

No setpoint voltage

Check the controller and con-
nection

VPPE-... fault

Send the device to the Festo
repair service

Flow rate too low

Restriction of the flow cross
section due to connection tech-
nology (swivel fittings)

Use alternative connections

Pressure constant despite
modified setpoint specification

Supply cable breakage; the last
output pressure set is main-
tained but not regulated. Slow
pressure change at output pos-
sible

Replace supply cable

Harsh switching noise of the
VPPE-...

Input pressure p1 not present

Increase input pressure p1 to
at least 0.1 MPa above output
pressure p2.
Monitor maximum permissible
operating pressure of 0.8 MPA.

Tab. 7: Causes and remedies for malfunctions

11.1

Reset to factory settings

NOTICE

Resetting to the factory settings will lose the current settings.
• If required, make a note of these settings before reset.

Reset [rES] restores the factory setting. Press and hold "

v

 + 

V

 + Edit" and then

switch on the device.
The following parameters are then set:

Parameter

Setting/value

x.xx

Permanent display for actual value or setpoint value

Pr2

(universal control behaviour)

bar

bar

OFS

000

rnG

for 1 MPa type: 10
for 0.6 MPa type: 6
for 0.2 MPa type: 2

Frc

Display shows existing pressure at pressure output (p2)

An

Output: analogue

Eco

OFF

Pin

OFF

Tab. 8: Parameters after reset