Error
code
1)
Event type LED dis-
play
Status
2)
Description
Remedy
37
Warning
Flashing
Illumin-
ated
Switching frequency of
the air saving function
lies above the critical
limit (1 Hz)
–
Deactivate air sav-
ing function.
–
Check for leakage.
62
Warning
Flashing
Illumin-
ated
Evacuation or ventila-
tion time exceeded in 3
consecutive cycles
–
Check for leakage.
62
Error
Flashing
Flashing
Evacuation or ventila-
tion time more than
doubled
–
Check for leakage.
–
Extend air supply
time.
–
Check throttle set-
ting.
111
Warning
–
Flashing
Process quality below
critical limit
–
Check for leakage.
1) C bus errors are displayed in the bus node.
2) LED error LED lights up with every error
3) If an error occurs in the internal communication, no error code can be displayed.
Tab. 22 Error codes
10.2
Fault clearance
Fault description
Cause
Remedy
Device-independent vacuum
between workpiece and suction
gripper, ejector pulse not activ-
ated or sufficiently dimensioned
Activate ejector pulse when lift-
ing the suction gripper.
Increase duration and intensity
of ejector pulse
è
Tubing dimensioned incorrectly
Replace tubing (tubing dimen-
sions
è
Workpiece not released from
suction gripper
Flow control screw closed
Open flow control screw.
Operating voltage faulty
Apply permissible operating
voltage.
Electrical connections swapped
Connect device correctly.
No display
Device faulty
Replace device.
Incomplete display
Display faulty
Replace device.
Pressure indicator incorrect
Pneumatic connections
swapped
Connect device correctly
è
Malfunctions
29
Festo — VABF-S4-...-CB-VH/VL-... — 2019-05