Festo SPAN-B Series Скачать руководство пользователя страница 1

Translation of the original instructions

© 2020 all rights reserved to Festo SE & Co. KG

1

About this document

1.1

Applicable Documents

All available documents for the product 

è

 www.festo.com/sp.

2

Safety

2.1

General safety instructions

Only use the product in original status without unauthorised modifications.

Only use the product if it is in perfect technical condition.

Only use media in accordance with the specifications 

è

 Technical data.

Observe labelling on the product.

Note that changes to the switching status (EDIT mode) become effective
immediately.

2.2

Intended use

The product is intended for monitoring the pressure of compressed air and inert
gases in the piping.

2.3

Training of qualified personnel

Work on the product should only be conducted by qualified personnel.

3

Service

Contact your regional Festo contact person if you have technical questions

è

 www.festo.com.

4

Product overview

4.1

Function

The sensor converts pneumatic pressure values (relative pressure) into electrical
signals, which can be used for control or regulating functions. Measurements are
carried out using a piezoresistive sensor element with a downstream electronic
evaluation unit. The connection to the higher-level system is established via a
switching output.
The switching output can be configured to monitor a threshold value or a pressure
range. The PNP or NPN and the normally open (N/O) or normally closed (N/C) out-
put can be optionally set in this process.

4.1.1

Operating statuses

Operating status

Function

RUN mode

Basic status after the operating voltage is switched on

Display of the current measured value

SHOW mode

Display of the current settings

EDIT mode

Setting or modification of parameters

TEACH mode

Acceptance of the current measured value to determine
switching points

Tab. 1

4.1.2

Switching functions

Threshold value comparator for monitoring of a pressure threshold _|¯

Function

N/O (normally open)

N/C (normally closed)

Switching function:

1 switching point (SP)

TEACH mode:

2 teach points (TP1, TP2)

SP = ½ (TP1+TP2)

TP1            TP2

HY

1

0

Out

p

SP

TP1              TP2

SP

HY

1

0

Out

p

Tab. 2

Window comparator for monitoring of a pressure range _|¯|_

Function

N/O (normally open)

N/C (normally closed)

Switching function:

2 switching points (SP.Lo,
SP.Hi)

TEACH mode

1)

:

2 teach points (TP1, TP2)

TP1 = SP.Lo, TP2 = SP.Hi

 HY                  HY

TP1=SP.Lo   TP2=SP.Hi

1

0

Out

p

 HY                   HY

TP1=SP.Lo   TP2=SP.Hi

1

0

Out

p

1) SP.Lo = lower pressure/vacuum value, SP.Hi = higher pressure/vacuum value, dependent on the Teach

sequence

Tab. 3

4.2

Configuration

4.2.1

Product design

1 Display

2 A pushbutton

3 EDIT pushbutton

4 B pushbutton

5 Pneumatic port

6 Electrical connection

Fig. 1 Product design

5

Installation

5.1

Mechanical and pneumatic

NOTICE!

An unfavourable mounting position may impair the function of the product.

Mount the sensor so that condensation from the compressed air lines cannot
accumulate in the device.

Install the sensor so that it cannot be heated above the maximum permissible
operating temperature (plan for convection possibilities).

Remove all transport packaging. The material used in the packaging has been
specifically chosen for its recyclability.

Avoid applying force to the sensor housing during mechanical and pneumatic
assembly.

SPAN-B-…-G18M/R18M

Seal connecting thread.

Fig. 2 Example with G18M

8140082

SPAN-B

Pressure sensor

8140082
2020-06
[8140084]

Operating instructions

Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0