5. Commissioning
5−68
Festo P.BE−SFC−LAC−CO−EN en 0708NH
Parameters involved (record select)
The entries in the positioning table can be written via the field
bus (PNU 401
Ū
417).
The composition of the positioning table as per FHPP is
described in appendix B.2.7. Further record switching is
described in section 5.6.5.
Overview of parameters involved (see appendix B.2.7)
Parameters involved
Description
FCT
PNU
CI
Mode(absolute/relative/energy−optimized)
x
401
20E0/01h
Target position
x
404
20E0/02h
Speed
x
406
20E0/03h
Acceleration
x
407
20E0/04h
Deceleration
x
408
20E0/0Ah
Jerk when accelerating
x
409
20E0/05h
Mass of the effective load (without tool mass)
x
410
20E0/06h
Damping time
x
415
20E6h
20E0/07h
Jerk when braking
x
417
20E0/0Bh
Start (FHPP)
CPOS.B1 = positive edge: Start
Jogging and referencing have priority.
Reply message (FHPP)
SPOS.B2 = 0: Motion Complete
SPOS.B1 = positive edge: Acknowledge Start
SPOS.B4 = 1: Drive moves
Requirements
Device control by PLC/field bus
Controller must be in status Operation enabled"
Record number must be valid
Tab.5/16:
Parameters involved in Record Select mode
Содержание SFC-LAC CO Series
Страница 4: ...Contents and general instructions II Festo P BE SFC LAC CO EN en 0708NH...
Страница 10: ...Contents and general instructions VIII Festo P BE SFC LAC CO EN en 0708NH...
Страница 21: ...System summary 1 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 1...
Страница 41: ...Fitting 2 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 2...
Страница 47: ...Installation 3 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 3...
Страница 71: ...The control panel only type SFC LAC H2 4 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 4...
Страница 91: ...Commissioning 5 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 5...
Страница 171: ...Diagnosis and fault display 6 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 6...
Страница 188: ...6 Diagnosis and fault display 6 18 Festo P BE SFC LAC CO EN en 0708NH...
Страница 189: ...Technical appendix A 1 Festo P BE SFC LAC CO EN en 0708NH Appendix A...
Страница 195: ...Parametrizing in accordance with FHPP FPC B 1 Festo P BE SFC LAC CO EN en 0708NH Appendix B...
Страница 272: ...B Parametrizing in accordance with FHPP FPC B 78 Festo P BE SFC LAC CO EN en 0708NH...
Страница 273: ...Object directory DS204 and CI C 1 Festo P BE SFC LAC CO EN en 0708NH Appendix C...
Страница 319: ...Index D 1 Festo P BE SFC LAC CO EN en 0708NH Appendix D...
Страница 320: ...D Index D 2 Festo P BE SFC LAC CO EN en 0708NH Contents D Index D 1...