Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Page 277
Vision Sensor Manual
1
1
Reserve
1
Byte
Reserve
2
1
Reserve
1
Byte
Reserve
3
1
Reserve
1
Byte
Reserve
4
One block of 8, 16,
32, 64, 128 or 256
Bytes
Request
data
Byte-
array
Same data as for TCP requests, s.
addendum: ....
5.6.4.5 Module 5: „Response“ (From SBS to PLC)
Name in PLC „RESP (4 + 8/16/… bytes)“
Byte-
Position in
Module
Size in Bytes
Member
name
Data-
Type
Bit
number
Meaning
0
1
Key
U8
Response key which is mirrored from
request
1
1
Result
data
overrun
1 Bit
0
Response data has been truncated
Reserve 7 Bit
1-7
Reserve
2
1
Reserve
1
Byte
Reserve
3
1
Reserve
1
Byte
Reserve
4
One block of 8, 16,
32, 64, 128 or 256
Bytes
Result
data
Byte-
array
Same data as for TCP responses s.
addendum: …
5.6.4.6 Start- / End- criteria per each Profinet command
Command
(Modul
„Control“)
Start- condition (Modul
„Status“)
Confirmation of acceptance
(Modul „Status“)
Confirmation of execution
(Modul „Status“)
Trigger
Ready = High
Trigger Ack = High