Page 268
Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Vision Sensor Manual
Fig. 280: Connect SBS to PLC
5.6.3.5 Definition of I/O data
In the tab “Device view” as default the modules CTRL (Control) and STAT (Status) are active. As an
option the module DATA (Data module) can be added with a certain size of payload.
In the example: 2 Byte + 16 Byte payload (1Byte: Image ID; 1Byte: Result data overrun (s.
“Data” (From SBS to PLC) (Page 276)
), + 16 Byte payload data): If the data is longer than the defined range
the payload is truncated (in this case: Result data overrun = 1), if it´s shorter the rest of the 16 byte are
filled with 00h .
Fig. 281: Define I/O data
5.6.3.6 Set IP address of SBS in the project (Option 1)
The IP address of the SBS can be set via the project. Select option „Set IP address in the project“ and set
IP address. Address from the field “IP address” is written into the SBS. The IP address of the PLC and of
the SBS must not be the same, but must correspond, what means they have to be in the same address
range.
Содержание SBSC-EN
Страница 1: ......
Страница 161: ...Vision Sensor SBSI SBSC EN 8062650 1607b 13 09 2016 Page 161 Vision Sensor Manual Dot print Handwritten Industrial MICR ...
Страница 162: ...Page 162 Vision Sensor SBSI SBSC EN 8062650 1607b 13 09 2016 Vision Sensor Manual OCRA OCRB Pharma ...
Страница 306: ...Page 306 Vision Sensor SBSI SBSC EN 8062650 1607b 13 09 2016 Vision Sensor Manual Fig 319 Rescue 2 ...