86
Festo — MSE6-C2M — 2022-08b
Parameterisation
9.5
Read-only module parameters
Module parameter: module time of operation
Function number
4828 + m * 64 + 29, low byte
4828 + m * 64 + 30, high byte
m = module number 0
Description
The operating time of the function module in hours.
The operating time is the duration for which the module was supplied with
electrical energy.
Values
Unsigned binary number with the decimal value range:
0 … 65535 hours, low byte + 256 * high byte
Comment
The operating time is limited to a maximum value of 65535.
The operating hours counter is increased by 1 every time the operating voltage
is switched on and then when every additional hour elapses.
If the operation takes place more often than 65535 times, the parameter
remains at this value.
This parameter can only be read.
Tab. 77: Module time of operation module parameter
Module parameter: shut-off valve switching cycles ‘Shut off valve cycles’
Function number
4828 + m * 64 + 31 (low byte)
4828 + m * 64 + 32 (high byte)
m = module number 0
Description
Counts the switching cycles of the shut-off valve.
Values
Unsigned binary number with the decimal value range:
0 … 65535 cycles, low byte + 256 * high byte
Comment
The switching cycles counter is limited to a maximum value of 65535.
If the operation takes place more often than 65535 times, the parameter
remains at this value.
This parameter can only be read.
Tab. 78: Shut-off valve switching cycles module parameter
9.6
Parameterisation examples
9.6.1
Automatic shut-off function example
Every system must be set individually. The sample values are only intended as general orientation.