Assembly
17
1
2
Fig. 12: PFH
D
1
PFH
D
[10
-8
h
-1
]
2
Actuation rate (n
op
) [10
4
/a]
5
Assembly
5.1
Requirement
–
Take appropriate measures to remove any particles in the supply lines.
5.2
Preparation
NOTICE
In order to ensure electromagnetic compatibility in accordance with the EMC Directive, note the
following:
• Ensure a wall clearance of 32 mm, e.g. with the MS6-WPB mounting bracket.
• Do not lay cables between the wall and the product.
NOTICE
Loss of the safety function
Failure to comply with the minimum distance of 15 mm between the silencer and base can result in the
loss of the safety function.
• observe minimum distance of 15 mm below the silencer.
The free space ensures the exhaust can escape.
–
Place product as close as possible to the installation site.
–