![Festo MPS PA Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/festo/mps-pa/mps-pa_operating-instructions-manual_2283255041.webp)
Bottling Learning System
Sequence description
© Festo Didactic
696690
41
10.4.3
Manual mode
All actuators can be switched on in the Manual/Flow diagram menu on the control console (control elements
as switches). All analog values and the signal statuses of the sensors are displayed. In manual operation,
the station must be reported as busy so that liquid from an upstream station is not pumped into the tank. At
the same time, the STOP function is active at all times, which switches off all actuators.
Figure 21: Operating screen for manual operation
Notes
• The sequence can be interrupted at any time by pressing the EMERGENCY-STOP button or by
pressing the STOP button.
• The following applies when several stations are combined:
The individual stations are aligned in the order opposite the direction of material flow.