![Festo MPAC-VI Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/festo/mpac-vi/mpac-vi_manual_2284211041.webp)
5
Diagnostics and fault clearance
Festo – MPAC-VI-EN – 2017-12a – English
41
5
Diagnostics and fault clearance
5.1
Switching status indication of the solenoid coils
The LEDs on the valve covers show the switching statuses of the solenoid coils. The LEDs are depicted
symbolically in the following table. For the valve terminal, the LEDs are visible through the transparent
labelling 12 and 14 on the valve cover.
LED (yellow)
Switching position of the valve
Significance
off
Normal position
Logic 0 (signal not present)
LED (number)
is lit
Switching position
(normal case)
Logic 1 (signal is present, valve has switched)
Normal position (error)
Logic 1 (signal is present, valve has
not
switched):
– Operating voltage of the valves lies below
the permitted tolerance range
– Compressed air supply not OK
or
– Pilot exhaust is blocked
or
– Servicing required
Tab. 5.1
Meaning of the LED display