![Festo MPA-ASI Series Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/festo/mpa-asi-series/mpa-asi-series_manual_2284207184.webp)
A. Technical appendix
A−16
Festo P.BE−MPA−EN en 0802c
Electric components, MPA−S valve terminal with CPX terminal or CPI module
Electronic module VMPA...−FB−...
Operating voltage supply for electronic
components (V
EL/SEN
):
Nominal voltage
Max. intrinsic current consumption at 24 V
(internal electronics, all outputs 0 signal)
24 V DC ±25 %
8 mA
VMPA...−FB−EMG−...
VMPA...−FB−EMS−...
Load voltage supply valves (V
VAL
)
Nominal voltage
Max. intrinsic current consumption at 24 V
(internal electronics, without valves)
Diagnostic message undervoltage V
VAL
,
load voltage outside function range
24 V DC ±25 %
typ. 23 mA
Ţ
17.5
Ū
15.5 V
24 V DC ±25 %
typ. 3 mA
Ţ
17.5
Ū
15.5 V
Maximum current consumption per solenoid
coil out of load voltage V
VAL
at 24 V
MPA1
MPA2
Nominal pull current/duration
Nominal current with current reduction
58 mA / 20 ms
9 mA after 20 ms
99 mA / 20 ms
18 mA after 20 ms
Pressure sensor plate
Accuracy
Display step width
< ±2.5 % FS (full scale)
20 mbar
Proportional−DruckregelventilVMPA−6TA−...
Operating voltage supply
Nominal voltage
Current consumption
24 V DC (permitted residual ripple max. ±10 %)
max. 300 mA
Example of current calulation
Current consumption with two solenoid coils MPA2 switched in parallel and one electronics module
without
electrical isolation:
I
EL/SEN
= 20 mA
Rated pick−up current:
I
VAL
= 8 mA + 2 x 90 mA = 188 mA
Rated current with current reduction:
I
VAL
= 8 mA + 2 x 18 mA = 44 mA
Tab.A/10:
Technical specifications on electric components, MPA−S valve terminal with
CPX terminal or CPI module
Содержание MPA-ASI Series
Страница 2: ......
Страница 4: ...Contents and general instructions II Festo P BE MPA EN en 0802c...
Страница 8: ...Contents and general instructions VI Festo P BE MPA EN en 0802c...
Страница 18: ...Contents and general instructions XVI Festo P BE MPA EN en 0802c...
Страница 19: ...Summary of components 1 1 Festo P BE MPA EN en 0802c Chapter 1...
Страница 55: ...Fitting 2 1 Festo P BE MPA EN en 0802c Chapter 2...
Страница 71: ...Installation 3 1 Festo P BE MPA EN en 0802c Chapter 3...
Страница 106: ...3 Installation 3 36 Festo P BE MPA EN en 0802c...
Страница 107: ...Commissioning 4 1 Festo P BE MPA EN en 0802c Chapter 4...
Страница 128: ...4 Commissioning 4 22 Festo P BE MPA EN en 0802c...
Страница 129: ...Maintenance and conversion 5 1 Festo P BE MPA EN en 0802c Chapter 5...
Страница 169: ...Technical appendix A 1 Festo P BE MPA EN en 0802c Appendix A...
Страница 186: ...A Technical appendix A 18 Festo P BE MPA EN en 0802c...
Страница 187: ...Supplementary component summary B 1 Festo P BE MPA EN en 0802c Appendix B...
Страница 201: ...Index C 1 Festo P BE MPA EN en 0802c Appendix C...
Страница 202: ...C Index C 2 Festo P BE MPA EN en 0802c Contents C Index C 1...