Quickstepper
Festo FSS−12−C 0410a English
26
Stopping during a cycle
Use either an external button T−22−... and a front panel valve SV−3−M5 (chapter 11)
or a command module, e.g. the Festo Commander FSSC−12, to stop after a cycle.
S
In manual mode, use a button T−22−... and a front panel valve with normally−
open function. Actuating the button keeps the output loaded with compressed
air.
S
In automatic mode, stop the cycle by loading the input STOP
IN
on the Festo
Commander FSSC−12 and acutating the Stop button. Stop keeps the respective
output loaded with compressed air.
Emergency stop
Use an external pause button PR(S)−... and a front panel valve SV−3−M5 (chapter 11)
for an emergency stop setup. This also applies to automatic mode with a command
module, e.g. the Festo Commander FSSC−12.
S
In manual mode, cause an emergency stop to be applied by connecting the
output you want via an external pause button and a front panel valve with an
normally−closed function. Actuating an emergency stop switches off the air on
the output.
S
In automatic mode, bring about an emergency stop by loading the input
EMERGENCY STOP (NOT AUS) on the Festo Commander FSSC−12 and acutating
the external Pause button. Actuating an emergency stop switches off the
air on the output.
W
a
rnin
g
Observe the regulations in EN 418, i.e. ISO 13850.
Buttons, switches and the relevant front panel valves can be found in chapter 11.
Содержание FSS-12-C
Страница 18: ...Quickstepper Festo FSS 12 C 0410a Deutsch 18 ...
Страница 34: ...Quickstepper Festo FSS 12 C 0410a English 34 ...
Страница 50: ...Quickstepper Festo FSS 12 C 0410a Español 50 ...
Страница 66: ...Quickstepper Festo FSS 12 C 0410a Français 66 ...
Страница 82: ...Quickstepper Festo FSS 12 C 0410a Italiano 82 ...
Страница 98: ...Quickstepper Festo FSS 12 C 0410a Svenska 98 ...
Страница 99: ...Quickstepper Festo FSS 12 C 0410a 99 ...