3
Commissioning
Festo – EXCM-30/-40-...-PF-EN – 1603 – English
27
3.2.3
I/O interface [X2]
Communication with a higher-order controller (PLC/IPC) takes place through the I/O interface.
Note
The switching logic of the I/O interface is executed as PNP, based on IEC61131-2 for
PLC.
Connection
Pin
Function
1
6
10
5
11
15
1
RDYEN
Output
Ready for enable
2
DIN1
Input
Record selection
Records 1-…31
(Record 0 = homing)
3
DIN2
4
DIN3
5
DIN4
6
DIN5
7
24 V logic
Output
Logic v24 V
8
Start
Input
Start record or homing
9
ENABLE
Input
Enable drive and
operation
10
RESET
Input
Acknowledge error
11
ENABLED
Output
Drive and operation are
enabled
12
FAULT
Output
Error present
13
ACK
Output
Acknowledgment for
start signal
14
MC
Output
Motion complete
15
GND24
Logic voltage reference
potential
Tab. 3.3
Connection, I/O interface [X2]
3.2.4
CANopen interface [X3]
Connection X3
Pin
Function
5
9
6
1
1
–
Not used
2
CAN-L
Low signal
3
0 V (GND)
Reference potential
4
–
Not used
5
Screening
Screened connection
6
–
Not used
7
CAN-H
High signal
8
–
Not used
9
–
Not used
Tab. 3.4
Connection, CANopen interface [X3] to the controller