2
Overview
Festo – EXCM-30/-40-...-PF-EN – 1603 – English
19
2.9
General structure of the controller
1
2
3
4
5
6
7
8
9
aJ
aA
1
Mounting slots
2
Connection side to the planar surface gantry
3
Mounting slots
4
Functional earth connection
5
Voltage supply [X1] connection
6
I/O interface [X2]
7
Switch-off functions interface [X4]
8
Ethernet interface [X5]
9
7-segment display
aJ
LED indicators
aA
CANopen interface [X3]
Fig. 2.9
General structure
2.9.1
Interfaces
The controller has three interfaces in order to communicate with a higher-order controller:
–
I/O interface
–
CANopen interface
–
Ethernet interface
The active control interface is established via the Festo Configuration Tool (FCT) (
è