Electrical installation
Festo – EXCM-10/-30-...-E-EN – 1612b – English
31
4.2.7
Encoder connection
An incremental encoder with signals in accordance with RS422 can be connected to the encoder port.
Connection
Pin
Function
5
9
6
1
1
Incremental encoder signal A+,
Positive polarity
2
B
Incremental encoder signal B+,
Positive polarity
3
Incremental encoder signal zero pulse,
Positive polarity
4
0 V
Reference potential
5
+5 V ±10 %
Supply of the encoder.
Max. 100 mA, not secure against short
circuit.
6
A/
Incremental encoder signal A–,
Negative polarity
7
Incremental encoder signal B–,
Negative polarity
8
Incremental encoder signal zero pulse,
Negative polarity
9
–
–
1)
Each 5 V; Ri = approx. 120 Ω
Tab. 4.8
Encoder connection
4.2.8
Motor connection
Port
Pin
Function
1
6
1
6
Interface at the controller
Plug on connection side
1
String A
Connection of the two motor strings
2
String A/
3
String B
4
String B/
5
BR+
Connection of the holding brake.
Short-circuit- and overload-protected.
BR– = GND,
BR+ is switched (24 V load)
6
BR–
1)
Next to the motor connections is an M4 threaded pin to connect the screening of the motor cable through a cable lug
Tab. 4.9
Motor connection