![Festo EMCS-ST Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/festo/emcs-st/emcs-st_operating-instructions-manual_2283346077.webp)
Process parameters
System parameters
Description
"Mov
In
"
"Mov
Out
"
System commands
0x0029.1
0x0029x2
0x0002
–
In end-to-end operation with press func-
tion, the drive travels from the "Start
Press" position towards the "Lim
Out
" end
position under force control.
–
After a restart, the reference end position
"Ref" is re-initialised first.
true
false
Mov
In
0xC8
(200)
Control command for executing the motion
"Mov
In
".
–
The drive moves position-controlled
towards the "Lim
In
(Ref)" end position.
–
After a restart, the reference end position
"Ref" is re-initialised first.
true
true
Disable power stage
0xCB
(203)
Control command for switching off the power
stage.
–
The power stage is switched off immedi-
ately.
–
The drive coasts to a standstill.
–
At standstill, the drive remains stopped
unregulated.
Tab. 39 Control data via IO-Link
14.2.6
Monitor end-to-end operation via IO-Link
The current position of the drive in end-to-end operation can be monitored via the process paramet-
ers. The following table shows the process commands for monitoring the drive position.
The following table shows the combinations of the process parameters "State
In
" and "State
Out
" via IO-
Link for monitoring the drive in end-to-end operation.
Process parameters
Description
"State
In
"
0x0028.1
"State
Out
"
0x0028.2
false
false
–
The drive is not in the "Lim
In
(Ref)" or "Lim
Out
" end position.
false
true
–
The drive is in the "Lim
Out
" end positions.
–
The drive has reached the set force in the force-controlled range of
end-to-end operation with press function.
true
false
–
The drive is in the "Lim
In
(Ref)" end positions.
true
true
–
critical error
è
13.2.2 Diagnostic messages and fault clearance.
Tab. 40 Status data via IO-Link
IO-Link
77
Festo — EMCS-ST — 2020-04a
Содержание EMCS-ST
Страница 1: ...8123666 EMCS ST Integrated drive 8123666 2020 04a 8123668 Operating instructions ...
Страница 29: ...11 1 2 Dimension reference system Drive system 29 Festo EMCS ST 2020 04a ...
Страница 48: ...Fig 22 Single end to end operation Drive system 48 Festo EMCS ST 2020 04a ...
Страница 50: ...Fig 23 Stop and continue single end to end motion Drive system 50 Festo EMCS ST 2020 04a ...
Страница 54: ...Fig 25 End to end operation with press function Drive system 54 Festo EMCS ST 2020 04a ...
Страница 56: ...Fig 26 Stop and resume end to end travel with press function Drive system 56 Festo EMCS ST 2020 04a ...