6
PROFINET IO with FHPP
108
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
6.5.3
Setting of FPC and FHPP+ (optional)
In addition to the controller and status data, the following data can also be transmitted:
–
Festo Parameter Channel (FPC)
è
–
Expansion of the FHPP standard data (FHPP+)
è
Configuration and parameterisation are performed using the Festo Configuration Tool (FCT), page
“Fieldbus”, register “FHPP+ Editor”.
6.6
Commissioning with the Festo Configuration Tool (FCT)
The first time the EMCA enters service is via the Festo Configuration Tool (FCT)
è
FCT help for Plu
gIn EMCA.
Note
With activation of FCT in the device control, the Festo Configuration Tool (FCT) takes
over master control via the EMCA. PROFINET communication to the controller remains
enabled via the PROFINET interface [X2/X3] but PROFINET has no master control.
6.6.1
Permanent storage of network settings and device name
The saving of network settings and device name can take place in the PROFINET master and also in the
EMCA.
The precise procedure depends on the currently prevailing situation in the device:
Protocol
Description
Festo Configuration Tool (FCT)
Initial start-up via
FCT
The Festo Configuration Tool (FCT) can be used to establish an Ethernet connec
tion between PC and EMCA [X1]. Via this connection, the network configuration
can be transmitted, and saved in the EMCA in a permanent manner.
Changing the net
work configura
tion via FCT
Changes to the network configuration in the Festo Configuration Tool (FCT) can
be transmitted over the Ethernet interface [X1] to the EMCA. To enable this
change, the EMCA must save the data in a permanent manner. Data are then
adopted after a subsequent “Reboot the controller” in the FCT.
DCP protocol
Changing the net
work configura
tion via DCP
With the DCP protocol, a new network configuration can be assigned to the
EMCA. Using the DCP protocol, the device that assigns the network configura
tions can define whether the IP address should be saved permanently in the
EMCA. The modified parameters are adopted without a reboot.
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......