background image

Translation of the original instructions

© 2020 all rights reserved to Festo SE & Co. KG

IO-Link

®

 is a registered trademark of its respective trademark holder in certain

countries.

1

About this document

1.1

Applicable Documents

All available documents for the product 

è

 www.festo.com/sp.

Type

Product

Contents

EMCS-ST

Integrated drive

Operating instructions

ELGC-BS

Spindle axis

Operating instructions

EAMM-A

Axial kit

Assembly instructions

NEFC-M12G8-0.3-M12G5-LK

Adapter

Assembly instructions

Tab. 1 Other Applicable Documents for the Product

2

Safety

2.1

Safety instructions

Observe labelling on the product.

Prior to assembly, installation and maintenance work: Switch off power sup-
ply, ensure that it is off and secure it against being switched back on.

Store the product in a cool, dry, UV-protected and corrosion-protected envir-
onment. Ensure that storage times are kept to a minimum.

Observe tightening torques. Unless otherwise specified, the tolerance
is ± 20 %. 

2.2

Intended Use

The spindle axis unit ELGS-BS is designed for linear movement of payloads or as a
drive when external guides are used between two end positions.
The spindle axis unit ELGS-BS is approved for slide operation.

Fig. 1 Slide mode

2.3

Training of qualified personnel

Installation, commissioning, maintenance and disassembly should only be con-
ducted by qualified personnel.
The personnel must be familiar with the installation of mechatronic control sys-
tems.

3

Further information

Accessories 

è

 www.festo.com/catalogue.

Spare parts 

è

 www.festo.com/spareparts.

4

Service

Contact your regional Festo contact person if you have technical questions

è

 www.festo.com.

5

Product overview

5.1

Scope of Delivery

The following components are included in the scope of delivery:

Spindle axis unit ELGS-BS

Instruction manual for the spindle axis unit ELGS-BS

Adapter for IO-Link operation (optional accessory)

è

 www.festo.com/catalogue

5.2

System overview

1 PELV fixed power supply for load

voltage

2 PELV fixed power supply for logic

voltage

3 Application software

4 PC or Laptop

5 Controller or IO-Link master

6 Spindle axis unit ELGS-BS

Fig. 2 System Overview

Items 

1

 … 

5

 are not in the scope of delivery.

5.2.1

Product design

1 Spindle axis ELGC-BS

2 Axial kit EAMM

3 Product labelling

4 Integrated drive EMCS-ST

5 Controller housing

6 Warning symbol "Attention! Hot

surface"

Fig. 3 Product design

Electrical connections, display and operating components (HMI)

1 LED display Menu

(Speed Out, ..., Demo) 

2 LED parameter display

3 LED C/Q

4 Connection for load voltage

[Power]

5 Logic voltage and digital I/O or

IO-Link connection [Logic]

6 Pushbutton actuator (right arrow)

7 Pushbutton actuator (Edit)

8 Pushbutton actuator (left arrow)

Fig. 4 Electrical connections, display and operating components (HMI)

6

Transport

NOTICE!

Unexpected and unbraked movement of components

Secure moving components for transport.

1. Take product weight into account 

è

 13 Technical data.

2. Maintain support clearance 

£

 300 mm when attaching transportation aids.

7

Assembly

WARNING!

Risk of injury due to unexpected movement of components.

The drive can move freely in the voltage-free state. This can cause unexpected
movements of the connected mechanics and crush parts of the body.

Bring moving parts of the mechanical system into a safe position.

8133151

ELGS-BS

Spindle axis unit

8133151
2020-03a
[8133153]

Operating instructions

Festo SE & Co. KG 
Ruiter Straße 82 
73734 Esslingen 
Germany
+49 711 347-0 

www.festo.com 

Содержание ELGS-BS Series

Страница 1: ...ns è www festo com 5 Product overview 5 1 Scope of Delivery The following components are included in the scope of delivery Spindle axis unit ELGS BS Instruction manual for the spindle axis unit ELGS BS Adapter for IO Link operation optional accessory è www festo com catalogue 5 2 System overview 1 PELV fixed power supply for load voltage 2 PELV fixed power supply for logic voltage 3 Application so...

Страница 2: ...n objects out of the positioning range Perform commissioning with low dynamic response WARNING Severe irreversible injuries from accidental movements of the connected actu ator technology Unintentional movements of the connected actuator technology can result from exchanging the connecting cables of a servo drive or between servo drives Before commissioning All cables must be correctly assigned an...

Страница 3: ...C 4 false Menu function with pushbutton actuators select selecting menu press Parameterise setpoint values Speed Out Speed In and Force Set value 10 20 100 of maximum value è 13 Technical data and save Save press Parameterise the position of the reference end position Ref Set Ref and run the homing movement MovRef StartRef PosAct è LimIn è LimOut press Run Start Press movement Start Stop and save ...

Страница 4: ...esto 0x1000 0x000F 15 I2t monitoring power stage error 0x1805 0x0016 22 Logic voltage undersupply2 0x1804 0x0017 23 Logic voltage oversupply 0x1803 0x0026 38 Load voltage undersupply or not connected 0x1802 0x0027 39 Load voltage oversupply 0x1801 0x0031 49 Device undertemperature 0x0033 51 Device overtemperature 0x4000 0x012F 303 IO Link connection lost red light z 1 Additional information è Desc...