Festo DFPI ND2P-E-NB3 Series Скачать руководство пользователя страница 4

12

Malfunctions

NOTICE!

Repairs to the product are not permissible. In the event of malfunctions or failure:
Replace the product and let Festo know about the failure. Return defective
products to Festo.

Fault description

Cause

Remedy

Piston rod does not move in the
desired direction

Displacement encoder cable
incorrectly connected at posi-
tioner or DFPI.

Correct the connection

Piston rod does not move in the
desired direction

Compressed air connections
connected incorrectly

Correct the connection

Tab. 10

13

Disassembly

1. Switch off the power supply (operating medium, electrical power supply).
2. Disconnect electrical and pneumatic connections.
3. Undo the retaining screws of the drive and remove the drive.

14

Disposal

ENVIRONMENT!

Send the packaging and product for environmentally sound recycling in accord-
ance with the current regulations 

è

 www.festo.com/sp.

15

Technical data

DFPI-...

-100

-125

-160

-200

-250

-320

Type of mounting

Mounting interface in accordance with ISO 15552

Spanner size on the piston rod

22

27

36

36

46

55

Stroke

[mm]

40 … 990

Min./max. stroke allowance

[mm]

0 … 4

Design

Piston rod, cylinder barrel

Cushioning

No cushioning

Mounting position

any

Mode of operation

double-acting

Position detection

With integrated displacement encoder

Displacement encoder measuring principle – potentiometer (DFPI-...-NB3...)

Operating voltage range

[V DC]

0 … 15

Independent linearity

[% FS]

_

 0.04

Hysteresis

[mm]

0.33

Repetition accuracy

[mm]

_

 0.12

Resistance value of displacement encoder (at TET) dependent on stroke length

1)

≤ 290 mm

[kΩ]

5

> 290 … 590 mm

[kΩ]

10

> 590 … 990 mm

[kΩ]

20

Recommended current at the displacement encoder

Recommended slider current

[µA]

< 0.1

Max. short-time slider current

[mA]

10

Displacement encoder measuring principle – potentiometer with integrated transmitter (DFPI-...-
NB3...-T)

Power Supply

2-wire

Analogue output

[mA]

4 … 20

Operating voltage range

[V DC]

0 … 30

Reverse polarity protection

Yes

Independent linearity

[% FS]

_

 0.05

Hysteresis

[mm]

0.4

Repetition accuracy

[mm]

0.7

Electrical connection

DFPI-...-NB3P

DFPI-...-NB3P9

Straight plug; 3-pin; screw terminal

DFPI-...-NB3M12

Plug M12x1, A-coded

DFPI-...-NB3P-T

DFPI-...-NB3P9-T

Terminal strip; 2-pin

DFPI -...- NB3M12-T

Plug M12x1, A-coded

Pneumatic port

DFPI-...-NB3P-...

for tubing outside 

Æ

 8 mm

DFPI-...-NB3P9/M12-...

Air connection G

y

Operating pressure

[bar]

3 … 8

Nominal operating pressure

[bar]

6

Operating medium

Compressed air in accordance with ISO 8573-1:2010
[7:4:4]

Note on the operating medium

lubricated operation possible
(required in further operation)

DFPI-...

-100

-125

-160

-200

-250

-320

Degree of protection in mounted
state

IP65, IP67, IP69K, NEMA 4

Ambient temperature

[°C]

–20 … +80

Product weight

Basic weight at 0 mm stroke

[g]

4900

7500

12800

18100

31100

57700

Additional weight per 10 mm
stroke

[g]

90

134

200

238

358

582

Moving mass at 0 mm stroke

[g]

1060

1900

3700

4800

9300

16500

Additional moving mass per
10 mm stroke

[g]

28

53

89

89

134

227

Information on materials

Cylinder barrel

Anodised wrought aluminium alloy

Cover (end cap)

Coated wrought aluminium alloy

Bottom cover (bearing cap)

Coated die-cast aluminium

Tie rods

high-alloy stainless steel

Piston rod

high-alloy stainless steel

Flange screws/nuts

Coated steel

Screws

Coated steel

high-alloy stainless steel

Rod bearing

Sintered bronze

Piston rod seal

PUR

NBR

Static seal

NBR

Note on materials

DFPI -...- NB3P: PWIS-free, RoHS-compliant

DFPI-...-NB3P9/M12: contains PWIS, RoHS-com-
pliant

Vibration resistance in accordance
with DIN/IEC 68 Part 2-6

0.35 mm path at 0 … 60 Hz;
5 g acceleration at 0 … 150 Hz

Continuous shock resistance as
per DIN/IEC 68 Part 2-82

_

 15 g at 6 ms duration; 1000 shocks per direction

1) TET = theoretical electrical travel

Tab. 11 Technical data

15.1

Max. permissible lateral forces for static applications

NOTICE!

In controlled operation, it may be necessary to adjust the max. lateral force to the
type of control.

Horizontal installation

Fig. 8 

Vertical installation

Æ

 100

Æ

 125

Æ

 160/200

Æ

 250

Æ

 320

Fig. 9 

Отзывы: