Festo DFPI ND2P-E-NB3 Series Скачать руководство пользователя страница 3

4. Thread the electrical connecting cable through the passage of the housing

(

è

 Fig.5, 

3

) and connect it.

DFPI -...- ND2P-E-NB3P (plug): 

è

 Tab. 3

DFPI -...- ND2P-E-NB3P-...-T (terminal strip): 

è

 Tab. 4

Pin allocation for DFPI -...- ND2P-E-NB3P (plug)

Pin

Allocation

Plug

1

Operating voltage –

2

Slider signal (piston position)

3

Operating v

Tab. 3 

Pin allocation DFPI-...-ND2P-E-NB3P-...-T (terminal strip)

Pin

Allocation

Terminal strip

Analogue output –

+

Analogue 

Tab. 4 

5. Only DFPI-...-ND2P-E-NB3P:

Fasten the connected plug to the electrical connection.
Tightening torque: 0.5 Nm ± 10%.

6. Mount the housing on the drive. Make sure that the seal (O-ring) is seated

correctly. Tightening torque for the retaining screws: 2.7 Nm ± 10%.

7. Connect the earth terminal (

è

 Fig.2

3

) to the earth potential with low

impedance (short cable with large cross-section).

8.2.2

DFPI-...-ND2P-E-NB3P9-...(-T)

The manifold block is fully assembled with the version with M16 cable connector.

1 M16 cable connector

2 Electrical connection with pre-

assembled plug(3-pin)

Fig. 6 DFPI-...-ND2P-E-NB3P9

1 M16 cable connector

2 Electrical connection with termin-

al strip (2-pin)

Fig. 7 DFPI-...-ND2P-E-NB3P9-T

1. Remove retaining screws from the cover 

è

 Fig.2, 

6

.

2. Disconnect the pre-assembled plug at the electrical connection.
3. Select appropriate electrical connecting cable.

DFPI-...-ND2P-E-...

-NB3P9

-NB3P9-...-T

Number of cores

3 (minimum)

2 (minimum)

Outside diameter

[mm]

4.5 … 10

Conductor cross section

[mm

"

]

0.75 … 1.5

Tab. 5 

4. Guide the electrical connecting cable through the M16 cable connector and

connect it.

DFPI-...-ND2P-E-NB3P9 (plug): 

è

 Tab. 6

DFPI-...-ND2P-E-NB3P9-...-T (terminal strip): 

è

 Tab. 7

Pin allocation for DFPI -...- ND2P-E-NB3P9 (plug)

Pin

Allocation

Plug

1

Operating voltage –

2

Slider signal (piston position)

3

Operating v

Tab. 6 

Pin allocation DFPI-...-ND2P-E-NB3P9-...-T (terminal strip)

Pin

Allocation

Terminal strip

Analogue output –

+

Analogue 

Tab. 7 

5. Tighten the cable connector. Tightening torque: 10 Nm.
6. Only DFPI-...-ND2P-E-NB3P9:

Fasten the connected plug to the electrical connection.
Tightening torque: 0.5 Nm ± 10 %

7. Mount the cover on the end cap. Make sure that the seal (O-ring) is seated

correctly. Tightening torque for the retaining screws 8 Nm.

8. Connect the earth terminal (

è

 Fig.2, 

3

) to the earth potential with low

impedance (short cable with large cross-section).

8.2.3

DFPI-...-ND2P-E-NB3M12-...(-T)

The plug is mounted on the manifold block with the version with M12 plug.

Connect electrical power supply to the M12 plug.

DFPI-...-ND2P-E-NB3M12 

è

 Tab. 8

DFPI-...-ND2P-E-NB3M12-...-T 

è

 Tab. 9

Pin

Assignment for DFPI-...-ND2P-E-NB3M12

Plug

1

Operating v

2

not assigned

3

Operating voltage –

4

Slider signal (piston position)

5

not assigned

1)

1) Stainless steel connection type (DFPI-...-ND2P-E-NB3M12V2) is only 4-pin. Pin 5 not present.

Tab. 8 

Pin

Assignment for DFPI-...-ND2P-E-NB3M12-...-T

Plug

1

Analogue 

2

Analogue output –

3

not assigned

1)

4

not assigned

1)

5

not assigned

1) Pin 3 and pin 4 are connected internally

Tab. 9 

9

Commissioning

Requirements

The drive is fully mounted and connected.

Commissioning the drive

1. Check operating conditions and critical limits 

è

 15 Technical data.

2. Provide power supply (operating medium, operating voltage).
3. Check correct function at first with a low travel speed.

10

Operation

WARNING!

Risk of injury due to unexpected movement of components.

Body parts in the movement range of the piston can be crushed or severed.

Protect the positioning range from unwanted intervention.

Keep foreign objects out of the positioning range.

Observe the operating conditions.

Comply with permissible critical limits.

11

Maintenance

When used as intended, the product is maintenance-free.

Отзывы: