Festo DFPI ND2P-E-NB3 Series Скачать руководство пользователя страница 2

Design of DFPI-...-ND2P-E-NB3P9/M12

1 Plug M12x1, A-coded

2 Pneumatic connection G 

y

(extend piston rod) 

3 Pneumatic connection G 

y

 (retract

piston rod) 

4 Air duct

5 Cable connector M16 x 1.5

Fig. 3 DFPI-...-…-ND2P-E-NB3P9/M12

6

Transport and storage

WARNING!

Danger of crushing. Danger of shearing.

Body parts can be crushed or severed if the product falls.

Use appropriate load handling equipment.

Do not use the air duct as a handhold for carrying.

When dispatching used products: comply with all legal requirements for the
handling of hazardous substances and the transport of dangerous goods. For
return to Festo 

è

 2.1 General Safety Instructions.

Remove all attachments.

Store the product in a cool, dry, UV-protected and corrosion-protected envir-
onment. Ensure that storage times are kept to a minimum.

7

Assembly

Any mounting position can be used.
1. Remove all transport packaging. The material used in the packaging has been

specifically chosen for its recyclability (exception: oil-impregnated paper =
residual waste).

2. Mount the drive with the retaining screws on the bearing cap and on the end

cap. Tighten the retaining screws evenly.

Tightening torques 

è

 Tab. 1.

Piston diameter

Tightening torque [Nm]

100

10

125

24

160

70

200

70

250

150

320

250

Tab. 1 

When using additional proximity sensors

NOTICE!

When linear drives are installed too close to each other, the cylinder magnet can
disturb the proximity sensor on the adjacent linear drive.

1. Mount sensor bracket on the tie rod.

Tightening torque: 0.6 … 1 Nm

2. Mount the proximity sensors 

è

 1.1 Applicable documents.

3. Check minimum distances to ferritic and magnetic materials. Position the

drive to ensure trouble-free operation.

4. Mount the drive.

When mounting accessory parts on the piston rod

1. Attach accessory parts to the male thread of the piston rod (

è

 Fig.2, 

9

).

2. Tighten nut and accessories.

8

Installation

8.1

Pneumatic Installation

8.1.1

DFPI-...-ND2P-E-NB3P

1 Pneumatic connection: retract

piston rod

2 Pneumatic connection: extend

piston rod

Fig. 4 

1. Prepare pneumatic connection.

Check whether check valves are required. These will prevent the move-
able mass from sliding down if the pressure drops in a vertical or inclined
mounting position.

Use outside-calibrated pneumatic lines with outside diameter of 8 mm
(e.g. Festo plastic tubing PUN-8x1.25).

Cut tubing ends at right angles and without burrs. This prevents damage
to internal O-rings.

2. Connect the linear drive to the compressed air connections 

è

 Fig.4.

Pay attention to the desired direction of movement of the piston rod.

Plug the tubing into the push-in fitting up to the stop.

Check that the tubing is securely held by pulling gently on it.

8.1.2

DFPI-...-ND2P-E-NB3P9/M12

1. Remove protective caps from the compressed air connections.
2. Connect pneumatic connecting cables (G

y

) to the compressed air connec-

tions 

è

 Fig.3.

8.2

Electrical installation

WARNING!

Risk of injury due to electric shock.

For the electric power supply, use only PELV circuits that ensure a reliable
electric disconnection from the mains network. 

Observe IEC 60204-1/EN 60204-1.

8.2.1

DFPI-...-ND2P-E-NB3P-...(-T)

1 Retaining screws

2 Seal (O-ring)

3 Opening for electrical and pneu-

matic connection (M32x1.5)

Fig. 5 Housing

1. Select appropriate electrical connecting cable.

DFPI-...-ND2P-E-...

-NB3P

-NB3P-...-T

Number of cores

3 (minimum)

2 (minimum)

Conductor cross section

[mm

"

]

0.75 … 1.5

Tab. 2 

2. Loosen retaining screws (

è

 Fig.5

1

) and remove housing.

3. Only DFPI-...-ND2P-E-NB3P:

Disconnect the pre-assembled plug at the electrical connection.

Отзывы: