Festo DFPD-HD-RD Series Скачать руководство пользователя страница 3

10

Maintenance

When used as intended, the product is maintenance-free.
Festo recommends the following periodic inspections:

Interval

Test

Annually

Correct function of the semi-rotary drive by
repeatedly opening and closing the valve fully
(rotation angle = 90°)

Every six months

Visual inspection (during operation)

Quarterly

Correct function of the semi-rotary drive during
operation

Tab. 4 

11

Malfunctions

In case of malfunctions, consult your regional Festo contact.

12

Dismounting

WARNING!

Danger of crushing.
Body parts can be crushed if the product falls.

Use appropriate load handling equipment.

Lift the semi-rotary drive using the transport lugs.

Before transporting: detach the semi-rotary drive from the process valve.

WARNING!

Risk of injury due to uncontrolled movement.

Before disassembling the semi-rotary drive: Depressurise the pipeline.

1. Disconnect the semi-rotary drive from the compressed air supply.
2. Loosen the pneumatic connections.
3. Undo the retaining screws on the semi-rotary drive.
4. Lift the semi-rotary drive off the process valve.

13

Disposal

Observe the local regulations for environmentally friendly disposal.

Dispose of the product in an environmentally friendly manner. When doing
this, also take residual media into account (recycling of hazardous waste
where appropriate).

14

Technical data

DFPD

Operating medium

Compressed air to ISO 8573-1:2010 [7:4:4]

1)

Note on the operating medi-
um

Lubricated operation possible (in which case lubricated
operation will always be required)

Ambient temperature

[°C]

–20 … +80

Rotation angle

[°]

0 … 90

Installation position

Parallel to line axis (DFPD-HD-...-HW horizontal only)

Pneumatic connection

G

½

, G1 (depending on cylinder size)

Standards-based connection
to fitting

ISO 5211

CE marking (see declaration of conformity

è

 www.festo.com/sp)

To EU Explosion Protection Directive (ATEX)
To EU Machinery Directive

Degree of protection

IP66M, IP67M

Operating conditions

Operating pressure

[bar]

3 … 8.5

Nominal operating pressure

[bar]

5.0 

_

 1

End position adjustment
range 0°

[°]

_

 5

End position adjustment
range 90°

[°]

_

 5

Material

Housing

Steel

Cover

Steel

Pneumatic cylinder

Steel (nickel-plated)

Piston rod

Steel (chrome-plated)

Piston

Steel

Tie rod

Steel

Stop cap

Steel

Stop adjusting screw

Steel

Seal

NBR, polyurethane

Top coat

Polyurethane

1) Pressure dew point at least 10°C below the outside temperature

Tab. 5 