Festo DeviceNet CMGA-E1-DN Скачать руководство пользователя страница 1

Description

Installation manual

Extension module
DeviceNet

761726
1201NH

Extension module

CMGA-E1-DN

Содержание DeviceNet CMGA-E1-DN

Страница 1: ...Description Installation manual Extension module DeviceNet 761726 1201NH Extension module CMGA E1 DN...

Страница 2: ...on how to avoid them Warning Dangers which can lead to death or serious injuries Caution Dangers which can lead to light injuries or to serious material damage Other symbols Note Material damage or lo...

Страница 3: ...g in the electronic data sheet file 6 4 2 2 Linking into the network diagram 7 4 2 3 Setting CMGA E1 DN 8 4 2 4 Configuration of the DeviceNet scanner 9 4 2 5 Linking into RSLogix 5000 10 4 2 6 Valida...

Страница 4: ...on regulations The applicable regulations and any other special safety regulations relevant to the particular ap plication must be strictly observed 2 2 User instructions Only install the module and p...

Страница 5: ...et A maximum of 2 CAN telegrams can be forwarded The module should be parametrised as a DeviceNet participant slave The DeviceNet baud rates of 125 kbps 250 kbps and 500 kbps can be set via the front...

Страница 6: ...e following example shows a commissioning with RSNetWorx 4 2 Project engineering First copy the supplied electronic data sheet file with icon into the corresponding Rockwell program directory 4 2 1 Li...

Страница 7: ...o GDCP CMGA E1 DN EN 1201NH 7 4 2 2 Linking into the network diagram The device Anybus IC DEV can be dragged into the diagram by drag and drop in the hardware menu under Vendor Fig 3 Linking into the...

Страница 8: ...P CMGA E1 DN EN 1201NH 4 2 3 Setting CMGA E1 DN By double clicking on Anybus IC DEV the following information can be displayed The only setting which must be made here is the issuing of the bus addres...

Страница 9: ...re 1756 DNB The I O parameters must be selected in the Scanlist menu Fig 5 Configuration of the DeviceNet scanner scanlist In the Input menu the input information 16 byte cyclic must be mapped in the...

Страница 10: ...ix 5000 In order to be able to validate the scanner data 1756 DNB the scanner must be linked into the I O configuration By selecting the module the saved network diagram can be loaded in the Module Pr...

Страница 11: ...the CMGA E1 DN data One can enable the Controller Tags window in the Logic menu Before the data can be validated the DeviceNet scanner must be set in the RUN mode This is done by setting the bit Loca...

Страница 12: ...9 Front of CMGA E1 DN 4 3 1 Address switch With these switches one can set the bus address up to max 63 and the DeviceNet baud rate The entry is made in hexadecimal Address HIGH Address LOW Baud rate...

Страница 13: ...ab 2 Coding switch terminating resistor Note If DeviceNet is being used both switches are to be set to OFF 4 4 Diagnostics LED Colour Mode Description RUN Green flashing Module OK DP Green permanent D...

Страница 14: ...Maintenance 5 1 Replacement of a module Note No plug in connection of the CMGA module must under any circumstances be discon nected or reconnected if it is live There is a danger of sensor damage par...

Страница 15: ...ient Tab 5 Technical data of the environmental conditions 6 2 Characteristic data Module CMGA E1 DN System running time 20 ms Number of CAN objects 2 Size of CAN telegrams 8 bytes CAN ID telegram 1 19...

Страница 16: ...t express authorization is prohibited Offenders will be liable for damages All rights reserved in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG Postfach...