DAPS−...
Festo DAPS−... 0707c English
25
After fitting the semi−rotary drive
6. Check that the semi−rotary drive turns in the required direction of rotation and
whether the processing valve assumes the required position.
7. If the semi−rotary drive does not turn in the required direction of rotation:
Carry out the following conversion:
Double−acting drives
Single−acting drives
1. Remove the pneumatic solenoid
valve.
2. Turn the solenoid valve 180°.
3. Note the position of the threaded
pin for orientating a NAMUR valve.
4. Fasten the solenoid valve again.
1. Remove the screws on the drive side.
2. Turn the drive 90° while it is still
connected via the shaft extension or
directly with the processing valve.
3. Tighten the fastening screws.
Содержание DAPS Series
Страница 87: ...DAPS Festo DAPS 0707c 87...