Group 0 − Configuration errors
CPX error group 100
(CPX-MMI: [Configuration error] )
No.
Message
Error level Reset type
01
The nominal configuration deviates from the actual configuration
F2
N
Note
The movement test is reset to avoid tubing connection errors. The CMAX has C03
status. The movement test should then be run once more.
Cause
A component on the axis string does not correspond to the nominal configuration:
–
displacement encoder or sensor interface (type, length)
–
cylinder (type, length, diameter)
–
valve type
Measure
Check component. Replace defective or incorrect components.
Adopt actual configuration (download).
Cause
The displacement encoder and valve have been exchanged and no longer match
the target configuration or the serial numbers have changed.
Measure
Check the axis configuration. Check to make sure 2 axis strings have not
been interchanged.
02
Unknown valve
F2
N
Cause
Connected valve is not supported.
Measure
Replace valve or
Update firmware.
03
Unknown cylinder
F2
N
Cause
Connected cylinder or sensor interface is not supported.
Measure
Replace cylinder or sensor interface.
Update firmware.
04
Unknown displacement encoder or unknown sensor interface
F2
N
Cause
Connected displacement encoder or sensor interface is not supported.
Measure
Replace displacement encoder or sensor interface.
Update firmware.
05
Project not loaded completely or block download active
F2
R
Cause
Drive cannot be enabled because the target configuration is not yet complete
(configuration status C00, C01 or C02).
Measure
Complete the target configuration, e.g. download project again.
Cause
Drive cannot be enabled because the block download is still active.
Measure
End block download. Check and correct the control program (parameterisation).